Schneider AS-HDTA-200 5-Slot Main Chassis
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 15305023276 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric / Modicon |
| Model | AS-HDTA-200 |
| Product Type | 5-Slot Main Chassis / Primary Subrack |
| Product Series | Modicon TSX Compact |
| Chassis Type | Primary Subrack |
| Number of Slots | 5 |
| CPU Slots | 2 |
| I/O Slots | 3 |
| Main Function | Provides mounting and backplane bus connections for PLC CPU and I/O modules |
| Backplane Type | Parallel backplane bus |
| Bus Functions | Data communication and 5 V DC power distribution |
| Bus Expansion | Supports connection to additional subracks through expansion cables |
| Compatible System | Modicon TSX Compact / 984 Compact |
| Expansion Capability | Supports additional I/O through compatible expansion subracks |
| Installation | Control cabinet mounting |
| Typical Applications | PLC control systems, industrial automation, I/O expansion |
| Product Status | Legacy / discontinued product |
| Dimensions | 245 × 180 × 110 mm |
| Weight | 0.2 kg |
FAQ
1. What is the main function of the Schneider AS-HDTA-200?
The Schneider AS-HDTA-200 is a 5-slot primary subrack designed for Modicon TSX Compact PLC systems. Its main purpose is to provide a physical mounting platform for the CPU and I/O modules while also providing the internal backplane connections required for communication and power distribution. Modules installed in the chassis communicate through the backplane rather than requiring individual point-to-point communication wiring. The AS-HDTA-200 is therefore a fundamental part of the PLC hardware architecture. It is typically used as the main chassis in a control system and can also be combined with compatible expansion subracks when additional I/O capacity is required.
2. How many module slots are available on the AS-HDTA-200?
The AS-HDTA-200 provides five module positions. The chassis configuration includes two positions associated with the CPU and three positions for I/O modules. This arrangement allows the processor and several I/O modules to be installed within the same primary chassis and communicate through the internal backplane. When configuring the system, each module should be installed in the correct position according to the applicable TSX Compact hardware configuration. If the application requires more I/O points than the main chassis can accommodate, compatible expansion subracks can be added to increase the overall I/O capacity.
3. Which PLC systems are compatible with the AS-HDTA-200?
The AS-HDTA-200 is primarily associated with Schneider Electric / Modicon TSX Compact PLC systems and related 984 Compact architectures. It is designed as a primary subrack for mounting compatible CPU and I/O modules and providing their backplane connections. Before replacing an existing chassis, the complete PLC configuration should be checked, including the CPU model, I/O module types, expansion hardware, and backplane requirements. Since TSX Compact is a legacy PLC platform, compatibility should be carefully verified when repairing an existing installation or planning a system modernization project.
4. What is the purpose of the backplane bus in the AS-HDTA-200?
The backplane bus provides the internal connection between the CPU and I/O modules installed in the AS-HDTA-200. It allows data to be exchanged between the processor and I/O modules and also distributes the required 5 V DC power within the chassis. Because multiple modules depend on the backplane for both communication and power, the condition of the backplane connection is important to overall PLC system reliability. A poor connection, damaged connector, or incorrectly seated module can result in communication errors or multiple modules failing to operate correctly. During maintenance, technicians should therefore inspect the module connectors and backplane interfaces carefully.
5. Can the AS-HDTA-200 be expanded with additional I/O modules?
Yes. The AS-HDTA-200 can be used as the primary chassis in a system that requires additional I/O capacity through compatible expansion subracks. An expansion subrack can be connected to the primary system using the appropriate I/O bus expansion cable, allowing additional I/O modules to participate in the PLC architecture. When designing an expanded system, the CPU capabilities, supported number of I/O modules, expansion chassis, bus cables, and overall system configuration must be considered together. The PLC configuration should also be updated so that the additional modules are correctly recognized and their I/O addresses are properly assigned.
6. What should be checked if several modules installed on the AS-HDTA-200 stop working at the same time?
If several modules become unavailable simultaneously, the problem should first be treated as a common system issue rather than assuming that multiple individual modules have failed. Start by checking the PLC system power supply and confirming that the CPU is operating normally. Next, inspect the connection between the CPU and chassis and verify that all modules are fully inserted into their correct positions. Since the backplane provides both communication and 5 V DC power distribution, the backplane and module connections should be carefully inspected. If the system also contains expansion subracks, the expansion bus cable and its connectors should be checked as well. Checking the common power and backplane connections before replacing individual modules can significantly reduce unnecessary component replacement.
7. What should be considered when replacing an AS-HDTA-200?
Before replacing the AS-HDTA-200, confirm that the replacement chassis matches the existing PLC architecture and that the CPU, I/O modules, and expansion hardware are compatible with it. The existing module positions and wiring should be documented before removal so that the replacement can be installed consistently. Power should be isolated according to the site’s maintenance and safety procedures before removing the chassis or connected modules. During installation, take care not to damage the backplane connectors, module contacts, or expansion cable connections. After installation, verify that all modules are correctly seated, restore power, and check the CPU and I/O status. A complete I/O communication test should be performed before returning the PLC system to normal operation.
8. What are common causes of backplane communication problems with the AS-HDTA-200?
Backplane communication problems can result from incorrectly seated modules, poor connector contact, contamination, abnormal power supply conditions, incompatible modules, or problems with the expansion bus connection. If only one module fails to communicate, the individual module and its corresponding slot should be checked first. If several modules fail simultaneously, attention should shift toward the common backplane, CPU connection, and power distribution. For systems using expansion subracks, the expansion cable and connectors should also be inspected. Because many TSX Compact installations have been operating for extended periods, connector aging, oxidation, mechanical vibration, and environmental exposure may also contribute to intermittent communication faults. A systematic check of the power supply, CPU, primary chassis, expansion connections, and individual I/O modules is the most effective way to isolate the problem.
Schneider AS-HDTA-200 5-Slot Main Chassis is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.