Allen Bradley 20BD096A3ANNANC0 PowerFlex 700 AC Drive

  • Manufacturer: Allen Bradley
  • Product Number: 20BD096A3ANNANC0
  • Condition: New & In Stock
  • Product Type: PowerFlex 700 AC Drive
  • Origin: USA
  • Payment Methods: T/T, Western Union
  • Dimensions: 689.6 x 308.9 x 275.4 mm
  • Weight: 37.19 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Model 20BD096A3ANNANC0
Product Type PowerFlex 700 AC Drive
Series PowerFlex 700
Input Voltage 480 VAC
Input Phase Three-phase
Input Frequency 60 Hz
Input Current 90.1 A
Input Power 74.9 kVA
Rated Output Current 96 A
Normal Duty Power Rating 75 HP
Heavy Duty Power Rating 60 HP
Frame Size Frame 5
Enclosure Rating IP20 / NEMA/UL Type 1
Conformal Coating Yes
Control Method Vector Control with 24V DC I/O
Feedback No Feedback
Human Interface LCD display with full numeric keypad
Communication Module No internal communication module
Brake IGBT Not included
Internal Brake Resistor Not included
EMC Filter Internal EMC filter with common-mode choke
Continuous Output Current 96 A
Heavy Duty Output Current, 1 minute 116 A
Heavy Duty Output Current, 3 seconds 154 A
Nominal Motor Voltage 460 V
Output Voltage Range 0–460 VAC
Maximum Output Frequency 420 Hz
Carrier Frequency 2, 4, 8, and 10 kHz; drive rating based on 4 kHz
Analog Inputs 2
Analog Outputs 2
Digital Inputs 6
Digital Outputs 3
Motor Overload Protection Class 10
Acceleration / Deceleration Time 0–3600 s, independently programmable
Speed Regulation Approximately 0.1% of base speed across a 120:1 speed range without feedback in Vector Control mode
Torque Regulation ±5% without feedback
Nominal DC Bus Voltage 648 VDC at 480 VAC input
DC Bus Overvoltage Trip 810 VDC at 480 VAC
DC Bus Undervoltage Fault 305 VDC at 480 VAC
Input Overvoltage Trip 570 VAC at 480 VAC
Input Undervoltage Trip 280 VAC at 480 VAC
Efficiency Approximately 97.5% at rated current and nominal line voltage
Maximum Short-Circuit Rating 200,000 A symmetrical
Dimensions 689.6 × 308.9 × 275.4 mm
Weight 37.19 kg

FAQ

1. What are the main electrical specifications of 20BD096A3ANNANC0?
20BD096A3ANNANC0 is a PowerFlex 700 AC drive designed for three-phase 480 VAC input power at 60 Hz. It has a 96 A continuous output current rating and is rated for 75 HP under normal-duty operation and 60 HP under heavy-duty operation. The nominal motor voltage is 460 V, with an output voltage range of 0–460 VAC. The drive is suitable for industrial motor speed and torque control applications where variable-frequency operation, adjustable acceleration, and controlled deceleration are required. The input current at 480 VAC is approximately 90.1 A, while the normal-duty input power rating is approximately 74.9 kVA. When selecting this drive for an application, the motor full-load current, operating duty, starting requirements, and mechanical load characteristics should all be considered rather than relying only on the horsepower rating.

2. What control method does 20BD096A3ANNANC0 use?
20BD096A3ANNANC0 uses Vector Control with 24V DC I/O and supports sensorless vector control as well as V/Hz control configurations. Vector Control provides improved speed regulation and dynamic response for applications that require more precise motor control. Without a feedback device, the drive can provide approximately 0.1% speed regulation of base speed across a 120:1 speed range under the specified Vector Control conditions. The drive can also provide approximately ±5% torque regulation without feedback. For proper performance, motor nameplate information must be entered accurately during commissioning. Incorrect motor voltage, current, frequency, or other motor parameters can result in unstable operation, excessive current, poor torque response, or unnecessary drive faults.

3. What are the normal-duty and heavy-duty ratings of 20BD096A3ANNANC0?
The normal-duty rating is 75 HP, while the heavy-duty rating is 60 HP. The normal-duty rating is intended for applications with relatively stable load conditions and moderate overload requirements. The heavy-duty rating should be considered for applications with higher starting torque, frequent acceleration and deceleration, or repeated short-duration overload conditions. The drive provides 96 A of continuous output current under its normal-duty rating, while the specified heavy-duty output capability is 116 A for one minute and 154 A for three seconds. When selecting between these operating categories, the actual motor full-load current and application load profile should be evaluated carefully. Using the normal-duty horsepower rating for an application that regularly demands heavy overload capacity can result in repeated overload protection and reduced operating reliability.

4. Does 20BD096A3ANNANC0 include a braking resistor or brake IGBT?
No. This configuration does not include a brake IGBT and does not have an internal braking resistor. This is an important consideration for applications involving high-inertia loads or frequent rapid deceleration. During deceleration, the motor can operate as a generator and return energy to the drive’s DC bus. The resulting increase in DC bus voltage can cause a bus overvoltage condition if the regenerated energy is not properly controlled. Applications such as conveyors with large inertial loads, hoisting equipment, winders, centrifuges, and other machinery requiring rapid stopping may therefore require an appropriately sized external braking solution. The braking system should be selected according to motor power, load inertia, maximum speed, deceleration time, and the frequency of braking events.

5. How should an overcurrent fault on 20BD096A3ANNANC0 be diagnosed?
When an overcurrent fault occurs, begin by checking the motor output circuit for phase-to-phase shorts, ground faults, damaged insulation, loose terminals, or incorrect wiring. The motor should also be checked for electrical abnormalities. After the electrical circuit has been verified, inspect the mechanical load for locked bearings, blocked transmission components, excessive friction, or sudden increases in torque demand. If the fault occurs mainly during acceleration, the programmed acceleration time may be too short for the load. The motor nameplate parameters should also be checked carefully, especially rated voltage, rated current, frequency, and motor-control settings. If the external wiring, motor, and mechanical system are normal but the drive continues to generate overcurrent faults, the output power section and current-sensing circuitry should be examined by qualified service personnel.

6. What should be checked when commissioning 20BD096A3ANNANC0 after installation?
Before applying power, verify the incoming three-phase supply, motor output connections, control wiring, grounding, and all power terminals. Once the drive is energized, check the display for active faults or alarms before issuing a run command. The motor’s nameplate parameters should then be configured accurately, including rated voltage, current, frequency, and power. The command source and speed reference source should also be verified because an incorrect source assignment can prevent the drive from responding to external control signals. Acceleration and deceleration times should be configured according to the machine’s mechanical characteristics. The initial test should preferably be performed at low speed or reduced load where the machine permits it. Motor direction, output current, operating frequency, acceleration, deceleration, and fault response should be verified before the machine is returned to full-load operation.

7. Why might 20BD096A3ANNANC0 fail to start the motor even when the input voltage is correct?
A correct input voltage does not necessarily mean that the drive has received a valid run command. First check whether the drive has an active fault, alarm, inhibit condition, or external interlock preventing operation. The 24V DC I/O signals should be checked to confirm that the configured start, stop, direction, and permissive inputs are receiving the expected signals. If a PLC or other controller is being used, its output logic and status should also be verified. The command source and speed reference source may have been configured incorrectly, or the speed reference may be below the programmed minimum operating frequency. Emergency-stop circuits, machine interlocks, and external permissive conditions should also be checked. If the drive recognizes the run command but produces no expected motor output, review the drive status parameters and fault history to determine whether the issue is related to control configuration, parameter settings, external wiring, or internal drive hardware.

8. How can the long-term reliability of 20BD096A3ANNANC0 be improved?
Long-term reliability depends on maintaining suitable electrical, thermal, and mechanical operating conditions. Output current, motor load, operating frequency, drive temperature, and fault history should be monitored regularly. The drive should not be continuously operated above its applicable current or duty rating. The IP20 / NEMA/UL Type 1 enclosure configuration also means that the installation environment should provide appropriate protection from excessive dust, moisture, oil mist, and other contaminants. Cooling airflow should remain unobstructed, and electrical terminals should be periodically inspected for looseness, oxidation, or signs of overheating. Repeated overcurrent, overvoltage, undervoltage, or overtemperature faults should be investigated to determine their root cause rather than being repeatedly reset. Correct motor parameters, stable power connections, proper grounding, adequate cooling, and a suitable load profile are all important for maintaining reliable operation of the drive and the connected motor system.

Allen Bradley 20BD096A3ANNANC0 PowerFlex 700 AC Drive is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.