Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 2080-IF2 |
| Product Type | Micro800 2-Channel Current/Voltage Analog Input Module |
| Product Series | Micro800 |
| Module Type | Plug-in Analog Input Module |
| Analog Inputs | 2 channels |
| Input Type | Single-ended, unipolar, non-isolated |
| Voltage Input Range | 0–10 V DC |
| Current Input Range | 0–20 mA |
| Input Impedance | Voltage mode: >100 kΩ; Current mode: 250 Ω |
| Resolution | Up to 12 bit |
| Data Range | 0–65535 |
| Overall Accuracy | Voltage: ±1% full scale @ 25°C; Current: ±1% full scale @ 25°C |
| Nonlinearity | ±0.1% full scale |
| Repeatability | ±0.1% |
| Module Error Over Temperature | Voltage: ±1.5%; Current: ±2.0%, -20 to 65°C |
| Channel Configuration | Configured through programming software or user program |
| Field Input Calibration | Not required |
| Update Time | 180 ms per enabled channel |
| Channel-to-Channel Isolation | None |
| Input Group-to-Bus Isolation | None |
| Power Consumption | <60 mA @ 3.3 V |
| Electrical Connection | Screw terminal connection |
| Recommended Maximum Shielded Cable Length | 10 m |
| Wire Size | Solid: 0.14–1.5 mm²; Stranded: 0.14–1.0 mm² |
| Terminal Screw Torque | 0.22–0.25 N·m |
| Mounting Torque | 0.2 N·m |
| Operating Temperature | -20 to 65°C |
| Non-Operating Temperature | -40 to 85°C |
| Operating Humidity | 5–95%, non-condensing |
| Operating Altitude | Maximum 2000 m |
| Safety Function | Not intended for safety functions |
| Dimensions | 62 × 20 × 31.5 mm |
| Weight | 0.021 kg |
| UPC | 885630058405 |
FAQ
1. What is the primary function of the 2080-IF2?
The 2080-IF2 is a two-channel plug-in analog input module for Allen-Bradley Micro800 controllers. It is designed to acquire industrial analog signals and make the corresponding digital values available to the controller for monitoring, processing, and control. Each channel supports either a 0–10 V DC voltage signal or a 0–20 mA current signal. Typical applications include pressure, flow, level, temperature transmitters, and other process instruments that provide standard analog outputs.
2. What analog input signals does the 2080-IF2 support?
The 2080-IF2 supports two primary analog input ranges: 0–10 V DC and 0–20 mA. Each channel can be configured according to the type of field device being connected. Voltage inputs are suitable for instruments providing standard voltage outputs, while current inputs are commonly used with industrial transmitters. Before commissioning, the input type should be matched correctly to the connected field instrument, and the controller program should use the appropriate scaling parameters for the selected signal range.
3. Are the two analog input channels on the 2080-IF2 electrically isolated?
No. The two analog input channels are non-isolated, and the input group is also not isolated from the controller bus. This means that particular attention should be paid to signal common connections, grounding, and the relationship between the field device power supply and the Micro800 controller. Where multiple field devices use different power sources or where significant ground-potential differences may exist, appropriate grounding, shielding, or signal isolation measures should be considered during system design.
4. What is the resolution of the 2080-IF2 analog input module?
The 2080-IF2 provides up to 12-bit analog-to-digital resolution and uses a unipolar input architecture. The module provides a digital data range of 0–65535. In an actual application, the raw digital value is normally scaled in the Micro800 program into an engineering value such as pressure, temperature, flow, or level. The resulting measurement accuracy also depends on the connected transmitter, field wiring, electrical noise, environmental conditions, and overall system configuration.
5. Does the 2080-IF2 require field calibration?
Field input calibration is not required for normal operation of the 2080-IF2. The module is designed to provide its specified accuracy when installed and operated within the applicable electrical and environmental conditions. During commissioning, however, technicians can verify the input using a known reference signal if the application requires additional confirmation. If a significant deviation is detected, the first checks should include the field transmitter output, input configuration, wiring, grounding, and electrical interference before considering a hardware fault.
6. What should be considered when wiring analog signals to the 2080-IF2?
First, confirm whether the field instrument provides a 0–10 V DC or 0–20 mA output and connect it to the appropriate input terminals. Because the module uses non-isolated inputs, the signal common and grounding arrangement should be carefully considered. Shielded cable is recommended for analog signal wiring, and the cables should be routed away from high-power circuits, motor cables, and variable-frequency drive output cables whenever practical. Terminal connections should be secure, and the complete signal loop should be checked before applying power to the system.
7. How should an unstable analog value from the 2080-IF2 be troubleshot?
Troubleshooting should begin by determining whether the field signal itself is stable. A suitable measuring instrument can be used to verify the transmitter’s actual voltage or current output. Next, check that the configured input type matches the physical signal and that the input remains within the specified range. Because the inputs are non-isolated, grounding problems, ground loops, and shared signal references should also be investigated. Shielding, cable routing, loose terminals, and proximity to high-frequency switching equipment can contribute to signal fluctuations. If the field signal is stable but the controller value continues to fluctuate, the raw input data, module status, and application program should be examined together.
8. How is the analog data from the 2080-IF2 used in a Micro800 program?
The 2080-IF2 converts the connected analog signal into digital data that can be processed by the Micro800 controller. With a data range of 0–65535, the raw value normally needs to be scaled according to the selected input range and the measuring range of the field instrument. For example, a 0–10 V signal can be converted into a pressure, temperature, flow, or level value, while a 0–20 mA signal can be converted according to the transmitter’s configured engineering range. The application program should also consider zero and full-scale values, abnormal input conditions, and out-of-range signals. For process-critical applications, additional signal validation and fault-detection logic can be implemented to prevent an invalid transmitter signal from directly affecting machine control.
Allen Bradley 2080-IF2 Micro800 2-Channel Current/Voltage Analog Input Module is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.