Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Honeywell |
| Model Number | 05704-A-0148 |
| Product Name | 5704F Fire Status Panel |
| Product Type | Fire Detection Status and Control Panel |
| Product Series | Honeywell System 57 |
| System Compatibility | Honeywell System 57 5704F Fire Control Cards |
| Main Function | Centralized fire alarm, fault, and system status indication |
| Display Indicators | Fire, Fault, Inhibit, Select, Walk Test, Earth Fault, Power |
| Indicator Type | LED |
| Audible Alarm | Built-in piezo sounder |
| Audible Alarm Frequency | Approximately 4 kHz |
| Audible Alarm Functions | Fire, Fault, Accepted Fire, Accepted Fault |
| Operating Controls | Accept, Silence, Reset, Lamp Test, Inhibit, Walk Test |
| Number of Push Buttons | 6 |
| Supply Voltage | 18–32 VDC, supplied by the Fire Control Card |
| Typical Power Consumption | 0.2 W |
| Maximum Power Consumption | 0.9 W |
| Operating Temperature | -5°C to +55°C |
| Storage Temperature | -25°C to +55°C |
| Operating Humidity | 20–90% RH, non-condensing |
| Installation | System 57 rack-mounted front panel |
| Installation Position | Immediately to the right of the associated Fire Control Card |
| Dimensions | 172 × 25 × 132 mm |
| Weight | 0.5 kg |
FAQ
Q1: What is the main function of the Honeywell 05704-A-0148 Fire Status Panel?
A: The Honeywell 05704-A-0148 is a centralized status indication and operator control panel designed for the System 57 5704F fire detection system. It collects common status information from the connected Fire Control Cards and displays important conditions such as Fire, Fault, Inhibit, Walk Test, and Earth Fault. The built-in audible sounder provides additional notification when fire or fault events occur. By combining visual indicators, audible alarms, and operator controls in one interface, it helps personnel monitor the overall fire detection system and respond to abnormal conditions efficiently.
Q2: Which Honeywell systems are compatible with the 05704-A-0148 Fire Status Panel?
A: This panel is designed for Honeywell System 57 installations equipped with 5704F Fire Control Cards. It connects to the associated Fire Control Card through a short flying lead and must be installed in the designated rack position, immediately to the right of the card. Only one Fire Status Panel is normally required for each rack. It works together with the Fire Control Cards and Engineering Card to provide common alarm indication and control functions. It is not a standalone fire controller and should not be used as a direct replacement for a Fire Control Card.
Q3: What alarm conditions can the 05704-A-0148 display?
A: The panel provides common LED indications for Fire, Fault, Inhibit, Select, Walk Test, and Earth Fault conditions, together with a green Power indicator. These indicators allow operators to identify the general operating status of the fire detection system without checking every individual control card. The audible sounder also provides different alert patterns for fire, fault, accepted fire, and accepted fault events. Operators should refer to the System 57 operating instructions to understand the meaning of each indicator and sounder pattern before performing maintenance or responding to an alarm.
Q4: What control functions are available on the Honeywell 05704-A-0148?
A: The Fire Status Panel has six front-panel push-buttons that support common operation and maintenance functions. These include Accept, Silence, Reset, and Lamp Test, as well as the channel-related Inhibit and Walk Test functions. Accept is used to acknowledge an alarm or fault notification, while Silence controls the audible alert according to the system operating logic. Reset is used to clear a condition after the cause has been addressed, and Lamp Test checks the operation of the visual indicators. Inhibit and Walk Test support controlled testing and maintenance activities. These functions should only be used by authorized personnel following site procedures.
Q5: How does the audible alarm work on the 05704-A-0148 Fire Status Panel?
A: The panel uses an integrated piezoelectric sounder to provide audible notification of important fire system events. Different operating patterns help distinguish between fire, fault, accepted fire, and accepted fault conditions. For example, a fire event uses a continuous sound, while fault and accepted-event notifications use intermittent patterns. This allows operators to recognize system conditions even when they are not directly looking at the panel. The sounder should be checked during scheduled maintenance to ensure that it operates correctly and that its audible output is not obstructed by surrounding equipment or excessive background noise.
Q6: How should the 05704-A-0148 be installed in a System 57 rack?
A: The panel must be installed as part of a compatible System 57 rack containing 5704F Fire Control Cards. According to the system configuration, it should be positioned immediately to the right of the associated Fire Control Card and connected through the supplied flying lead. Before installation, isolate the relevant power supply and follow the manufacturer’s electrical safety procedures. Check the connector, cable, and mounting position for damage or contamination. After installation, verify that the Power indicator operates correctly, the status LEDs respond as expected, and the audible sounder and front-panel controls function properly.
Q7: What should be checked if the Fire Status Panel does not display alarms correctly?
A: If the panel fails to display a fire or fault condition, first check whether the associated Fire Control Card is operating normally and receiving the correct power supply. Inspect the flying lead and connector for loose connections, damaged contacts, or incorrect installation. Next, check the relevant card configuration and confirm that the alarm condition is being generated correctly by the detection system. If the LEDs operate but the audible alarm does not, inspect the sounder and its associated circuitry. A fault in the Fire Control Card, rack connection, or system configuration may also affect the panel, so troubleshooting should cover the complete signal path rather than the status panel alone.
Q8: What maintenance practices help ensure reliable operation of the Honeywell 05704-A-0148?
A: Regular functional testing is important for maintaining reliable fire system indication. During scheduled maintenance, inspect the front-panel LEDs, push-buttons, audible sounder, flying lead, and electrical connector. Use the Lamp Test function to check the visual indicators and follow the approved system procedure to verify audible alarm and control-button operation. Check for loose connections, dust accumulation, corrosion, or signs of overheating. Walk Test and Inhibit functions should only be used under an authorized maintenance procedure, with appropriate precautions to avoid leaving fire detection channels disabled. Record test results and investigate any abnormal indication promptly to maintain the reliability of the overall fire detection system.
Honeywell 05704-A-0148 Fire Status Panel is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666084105 | |||||||
| +8613666084105 | ||||||||
| 13666084105 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.