Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Model | NS1000N |
| Product Type | Low Voltage Molded Case Circuit Breaker |
| Product Series | Compact NS630b…1600 |
| Rated Current | 1000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Insulation Voltage | 800 V AC |
| Rated Impulse Withstand Voltage | 8 kV |
| Number of Poles | 3P / 4P |
| Breaking Capacity Class | N – Normal Breaking Capacity |
| Rated Ultimate Short-Circuit Breaking Capacity | 50 kA at 415 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity at 220/240 V AC | 85 kA |
| Rated Ultimate Short-Circuit Breaking Capacity at 660/690 V AC | 30 kA |
| Rated Frequency | 50/60 Hz |
| Utilization Category | Category B |
| Trip Unit | MicroLogic Electronic Trip Unit |
| Protection Functions | LI / LSI / LSIG |
| Operating Mechanism | Manual or Electrical Operation |
| Mounting Type | Fixed or Drawout |
| Connection Type | Front Connection |
| Mechanical Endurance | Approximately 10,000 operating cycles |
| Protection Rating | IP40 |
| Applicable Standards | IEC 60947-1, IEC 60947-2 |
| Dimensions | 327 × 210 × 147 mm |
| Weight | 14 kg |
FAQ
1. What is the main function of the NS1000N circuit breaker?
The Schneider NS1000N is a high-current low-voltage circuit breaker designed for electrical protection and circuit control in industrial power distribution systems. It can connect and disconnect electrical circuits under normal operating conditions and protect equipment against overloads and short circuits when equipped with a compatible trip unit. When abnormal current conditions occur, the breaker interrupts the affected circuit to help prevent damage to cables, transformers, switchboards, and other connected equipment. It is suitable for industrial main distribution panels, large power feeders, and high-capacity electrical installations.
2. What is the rated current of the NS1000N?
The NS1000N has a rated current of 1000 A, making it suitable for high-current low-voltage power distribution applications. The actual operating current should be evaluated according to ambient temperature, load characteristics, conductor capacity, and installation conditions. Different trip unit configurations may provide different protection settings and adjustment ranges. When selecting a replacement, engineers should verify the complete product reference, rated current, number of poles, and trip unit configuration to ensure compatibility with the existing electrical system.
3. What is the short-circuit breaking capacity of the NS1000N?
The NS1000N belongs to the N breaking-capacity class. Its rated ultimate short-circuit breaking capacity is 50 kA at 415 V AC, 85 kA at 220/240 V AC, and 30 kA at 660/690 V AC, subject to the specific product version. These ratings indicate the maximum fault current the breaker can interrupt under specified test conditions. Before installation, the prospective short-circuit current at the installation point must be calculated. The selected breaker must have sufficient interrupting capacity for the electrical network, with proper coordination between upstream and downstream protective devices.
4. Which MicroLogic trip units are compatible with the NS1000N?
Depending on the exact configuration, the NS1000N can be equipped with different MicroLogic electronic trip units, including MicroLogic 2.0, 5.0, and 6.0 versions. These units offer different protection functions. MicroLogic 2.0 generally provides long-time overload and instantaneous short-circuit protection. MicroLogic 5.0 adds short-time protection, while MicroLogic 6.0 can also provide ground-fault protection. The available functions depend on the installed trip unit. Before replacing or upgrading a trip unit, verify its compatibility with the breaker frame, current rating, and protection requirements.
5. Why does the NS1000N trip frequently during normal operation?
Frequent tripping may be caused by excessive load current, downstream short circuits, high motor starting currents, incorrect protection settings, or ground faults. Loose electrical connections and deteriorated cable insulation can also create abnormal operating conditions. Troubleshooting should begin by checking the trip unit indication to identify which protection function has operated. Engineers should then measure the actual load current, inspect downstream circuits, examine electrical connections, and verify the trip settings. If the problem continues, the coordination between upstream and downstream circuit breakers should also be reviewed. Repeatedly resetting the breaker without identifying the fault is not recommended.
6. What is the difference between fixed and drawout NS1000N configurations?
The fixed version is installed directly onto a mounting structure inside the switchboard, with permanent main circuit connections. It is suitable for installations where the breaker does not need to be removed frequently. The drawout version uses a dedicated chassis that allows the breaker to be moved between connected, test, and disconnected positions. This arrangement makes inspection, maintenance, and replacement more convenient, particularly in large industrial power distribution systems. The two configurations have different mounting structures and connection accessories, so the original installation type must be confirmed before ordering a replacement.
7. Can the NS1000N be integrated with PLC, DCS, and power monitoring systems?
Yes. With compatible auxiliary contacts, electronic trip units, and communication accessories, the NS1000N can be integrated into industrial automation and power management systems. Auxiliary contacts can transmit breaker status signals to PLC or DCS controllers, while compatible electronic trip units may provide protection status and electrical measurement information. For remote switching applications, an appropriate motor operating mechanism and control circuit are required. Before integration, engineers should verify accessory compatibility, control voltage, signal characteristics, and communication protocols to ensure reliable operation within the existing automation system.
8. What maintenance procedures are recommended for the NS1000N?
Regular preventive maintenance helps maintain reliable operation and reduce unexpected power interruptions. Inspections should cover the main circuit terminals, insulation components, contact system, and mechanical operating mechanism. Check for overheating, corrosion, loose connections, contamination, and abnormal mechanical wear. The MicroLogic trip unit settings, fault records, and protection functions should also be checked periodically according to the manufacturer’s maintenance recommendations. If the breaker has interrupted a significant short-circuit current, its internal contacts and arc-extinguishing components should be professionally inspected before being returned to service. All maintenance work must be performed by qualified electrical personnel after proper power isolation and safety verification.
Schneider NS1000N Contactor is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666084105 | |||||||
| +8613666084105 | ||||||||
| 13666084105 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.