Technical Specifications
| Parameter | Specification |
|---|---|
| Model | PR122/P-LSIG E1-E6 |
| Ordering Number | 1SDA058198R1 |
| Product Type | Overcurrent Release |
| Manufacturer | ABB |
| Application | Low-voltage power distribution and industrial electrical protection systems |
| Main Function | Overcurrent protection, short-circuit protection, and selective protection control |
| Protection Type | L, S, I, G multifunction protection |
| Compatible Circuit Breakers | ABB Emax E1-E6 series circuit breakers |
| Installation Method | Internal installation within circuit breakers |
| Communication Capability | Supports industrial protection and monitoring functions |
| Control Method | Electronic protection control |
| Operating Voltage | Standard industrial low-voltage systems |
| Response Performance | High-speed fault detection and tripping response |
| EMC Protection | Industrial-grade electromagnetic compatibility protection |
| Environmental Adaptability | Suitable for industrial and power distribution environments |
| Cooling Method | Natural cooling |
| Material | Industrial-grade electronic components and reinforced housing |
| Dimensions | 155 × 95 × 70 mm |
| Weight | 1 kg |
FAQ
1. What is the primary function of PR122/P-LSIG E1-E6?
PR122/P-LSIG E1-E6 is designed to provide advanced overcurrent protection and control functions for low-voltage power distribution systems. The unit continuously monitors electrical conditions and can quickly detect overloads, short circuits, and ground faults. When abnormal current conditions are identified, it activates the connected circuit breaker to isolate the fault and protect electrical equipment, power lines, and connected systems from potential damage. Its protection capabilities help improve both operational safety and system reliability in industrial and commercial environments.
2. What do the LSIG protection functions represent?
The LSIG functions refer to Long-time protection (L), Short-time protection (S), Instantaneous protection (I), and Ground fault protection (G). These protection features work together to provide multiple levels of electrical fault protection. Long-time protection is used for overload conditions, short-time protection handles temporary high-current faults, instantaneous protection responds immediately to severe short circuits, and ground fault protection detects leakage currents that may cause safety hazards or equipment damage. This combination allows for highly selective and reliable protection coordination within complex power distribution systems.
3. Which applications commonly use this overcurrent release unit?
This protection unit is widely used in industrial power distribution systems, manufacturing plants, petrochemical facilities, data centers, commercial buildings, utility substations, and other critical electrical infrastructure. It is particularly suitable for applications where electrical safety, selective protection, and uninterrupted system operation are important. The device is commonly installed in systems requiring precise circuit breaker protection and advanced monitoring capabilities.
4. How can operational reliability be improved when using this device?
Operational reliability can be improved by ensuring proper installation, stable power conditions, and regular preventive maintenance. Electrical connections and terminal points should be inspected periodically to prevent loose wiring or overheating. Maintaining clean and dry control cabinet conditions, ensuring adequate ventilation, and avoiding excessive humidity or corrosive environments can also help extend the operational life of the protection unit. In addition, regularly verifying protection settings and system coordination improves long-term protection performance.
5. What should be checked if nuisance tripping occurs?
If nuisance tripping occurs, the first step is to verify whether the protection settings are correctly configured for the actual system load conditions. Current transformer connections, grounding integrity, and wiring quality should also be inspected carefully. In some industrial environments, electromagnetic interference or unstable power conditions may affect protection performance. Reviewing fault records and performing a detailed system diagnostic can help identify the root cause of unexpected trips.
6. Does the unit support selective protection coordination?
Yes, the device supports selective protection coordination through adjustable protection curves and timing parameters. This allows engineers to coordinate upstream and downstream circuit breakers so that only the breaker closest to the fault location trips during an electrical fault. Proper selective coordination helps minimize power interruptions, reduce equipment downtime, and improve overall power system stability and operational continuity.
7. What installation precautions should be followed for this overcurrent release?
During installation, the connected circuit breaker should be completely de-energized to ensure safety. All wiring and connections should follow the manufacturer’s electrical installation guidelines and industry standards. Signal wiring should be separated from high-power cables whenever possible to minimize electromagnetic interference. After installation, protection parameters and communication settings should be verified before placing the system into operation.
8. Is the device suitable for continuous long-term industrial operation?
Yes, the device is designed for continuous operation in demanding industrial and commercial environments. It uses industrial-grade electronic components and a robust protection architecture to maintain stable performance over extended operating periods. With proper environmental conditions, routine inspection, and preventive maintenance, the unit can provide reliable fault protection and fast response performance for critical electrical distribution systems over many years of service.
ABB PR122/P-LSIG E1-E6 1SDA058198R1 Overcurrent Release is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.