Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model MT25H1
Product Series Masterpact MT
Product Type Air Circuit Breaker (ACB)
Rated Current 2500 A
Breaking Capacity Class H1
Rated Operational Voltage Up to 690 V AC
Rated Frequency 50/60 Hz
Number of Poles 3P or 4P, depending on configuration
Rated Ultimate Short-Circuit Breaking Capacity (Icu) 65 kA at 440 V AC
Rated Service Short-Circuit Breaking Capacity (Ics) Configuration and voltage dependent
Protection Functions Overload and short-circuit protection
Trip Unit Configuration dependent
Mounting Type Fixed or withdrawable
Operating Mechanism Manual or electrically operated, depending on accessories
Control Unit Micrologic, depending on configuration
Isolation Function Suitable for isolation
Application Low-voltage power distribution and circuit protection
Applicable Standards IEC 60947-1, IEC 60947-2
Dimensions 441 × 395 × 439 mm
Weight 90 kg

FAQ

1. What is the main function of the Schneider MT25H1 circuit breaker?

The Schneider MT25H1 is a high-capacity low-voltage air circuit breaker from the Masterpact MT series. It is designed to protect electrical distribution systems against overloads and short circuits while providing reliable switching and isolation functions. With a rated current of 2500 A, it is suitable for main distribution boards, industrial switchgear, large commercial electrical installations, and critical power distribution systems. When an abnormal current condition occurs, the protection system detects the fault and initiates the tripping mechanism to disconnect the affected circuit. This helps reduce the risk of cable overheating, equipment damage, and electrical system failures.

2. What does the H1 breaking capacity designation mean?

H1 identifies the high breaking-capacity performance class within the Schneider Masterpact MT product family. For the MT25H1 configuration, the rated ultimate short-circuit breaking capacity is 65 kA at 440 V AC. This value indicates the maximum prospective short-circuit current that the circuit breaker can interrupt under the specified test conditions. The actual breaking capacity must always be considered together with the rated operational voltage and the complete breaker configuration. Engineers should distinguish between Icu, which represents ultimate breaking capacity, and Ics, which represents service breaking capacity. These values are important when selecting a circuit breaker for industrial distribution systems with high available fault currents.

3. What is the rated current of the MT25H1, and what applications is it suitable for?

The MT25H1 has a rated current of 2500 A, making it suitable for high-current low-voltage distribution applications. It can be used as a main incoming circuit breaker, busbar section breaker, generator connection breaker, or feeder protection device in industrial switchgear. Typical installations include manufacturing facilities, power distribution rooms, infrastructure projects, and large commercial buildings. When selecting this breaker, engineers must evaluate the continuous load current, expected short-circuit current, ambient temperature, busbar capacity, and coordination requirements with downstream protective devices. The 2500 A rating alone does not determine whether the breaker is suitable for a particular installation.

4. What protection functions does the Schneider MT25H1 provide?

The MT25H1 is designed to provide overload and short-circuit protection for low-voltage electrical distribution systems. Its actual protection functions depend on the installed trip unit and configuration. When the current exceeds the configured protection threshold, the trip unit evaluates the fault condition and sends a trip command to the circuit breaker’s operating mechanism. Depending on the installed Micrologic unit, additional protection functions and adjustable parameters may be available. During commissioning, engineers should verify long-time, short-time, and instantaneous protection settings where supported, as well as grounding protection if included in the selected configuration. Proper coordination with upstream and downstream breakers is essential to minimize unnecessary interruptions.

5. What is the difference between fixed and withdrawable MT25H1 configurations?

The MT25H1 can be supplied in fixed or withdrawable arrangements, depending on the selected configuration. A fixed circuit breaker is directly installed and connected within the switchgear compartment. Its removal generally requires isolation and disconnection of the associated electrical connections. A withdrawable version is installed in a compatible chassis and can be moved between connected, test, and disconnected positions. This arrangement makes inspection, maintenance, and replacement more convenient while reducing the need to dismantle the main switchgear connections. However, fixed and withdrawable versions are not automatically interchangeable. Before replacement, engineers must verify the frame compatibility, pole arrangement, connection system, chassis, and accessory configuration.

6. Can the MT25H1 be integrated into a PLC or DCS control system?

Yes. The MT25H1 can be integrated into PLC and DCS-based automation systems through compatible auxiliary contacts, status indication contacts, electrical operating accessories, and communication options where provided. Typical signals include breaker open/closed status, trip indication, spring-charged status, and remote operating commands. Depending on the installed accessories, the breaker may also support remote opening and closing through electrical control circuits. During integration, the control voltage, terminal assignments, interlocking logic, and feedback signal configuration must be checked carefully. For systems requiring centralized monitoring, compatible communication equipment may be used to exchange operating and diagnostic information with the supervisory control system.

7. What are the common faults of the MT25H1, and how should they be diagnosed?

Common problems include unexpected tripping, failure to close, failure to open, abnormal operating mechanism noise, and incorrect status indication. Unexpected tripping may result from actual overloads, short circuits, incorrect protection settings, or external control signals. If the breaker cannot close, technicians should inspect the spring-charging mechanism, closing coil, undervoltage release, electrical interlocks, and control power supply. Failure to open may involve a damaged shunt trip coil, mechanical obstruction, or problems in the trip circuit. Incorrect status feedback may be caused by defective auxiliary contacts or wiring faults. Diagnosis should begin with the trip history, protection unit indications, and control circuit checks. Internal inspection must only be performed after the breaker and associated circuits have been safely isolated.

8. What maintenance procedures are recommended for the Schneider MT25H1?

Regular preventive maintenance is essential for maintaining the reliability of the MT25H1 in high-current distribution systems. Maintenance personnel should inspect the main contacts, arc chambers, operating mechanism, electrical connections, auxiliary contacts, and protection unit. Check for signs of overheating, oxidation, mechanical wear, loose connections, or abnormal contact resistance. The opening and closing mechanisms should be tested to confirm smooth operation, and electrical accessories should be checked for correct response. The trip unit should also be inspected, and its protection settings should be compared with the approved electrical coordination study. For withdrawable versions, the chassis, guide rails, and connection contacts require additional inspection. After maintenance, perform the required functional and electrical tests before returning the breaker to service.

Schneider MT25H1 Contactor is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8613666084105
Whatsapp +8613666084105
WeChat 13666084105
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996