Schneider TSXDSZ08T2 Discrete Output Module
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 15305023276 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Discrete Output Module |
| Brand | Schneider Electric |
| Model | TSXDSZ08T2 |
| Product Type | Discrete Output Module |
| Product Series | Modicon TSX Series |
| Function | Provides digital output signals according to PLC control logic to operate industrial field devices |
| Output Type | Digital Transistor Output |
| Number of Output Channels | 8 Channels |
| Output Method | Solid-State Transistor Output |
| Rated Output Voltage | 24V DC |
| Load Type | Solenoid valves, relays, contactors, indicator lamps, and industrial actuators |
| Output Technology | Transistor Switching Output |
| Communication Method | PLC system backplane communication |
| Installation Method | PLC rack mounting |
| Module Design | Modular plug-in I/O design |
| System Compatibility | Schneider Electric Modicon TSX PLC systems |
| Diagnostic Function | Supports output status monitoring, module status indication, and fault diagnostics |
| Isolation Type | Electrical isolation between output circuits and internal control circuits |
| Response Time | High-speed digital signal switching for industrial automation applications |
| Power Supply | Supplied through PLC system backplane |
| Applications | Industrial automation, machine control, production lines, packaging systems, and process control |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -25°C to 70°C |
| Main Function | Receives PLC control commands and provides digital output signals for field equipment control |
| Dimensions | 260 × 180 × 57 mm |
| Weight | 0.329 kg |
FAQ
1. What is the primary function of the Schneider TSXDSZ08T2 Discrete Output Module?
The Schneider TSXDSZ08T2 Discrete Output Module is designed for Modicon TSX PLC systems to provide reliable digital output control between PLC logic and industrial field devices.
The module provides 8 transistor output channels that allow the PLC to control external devices such as solenoid valves, relays, contactors, and indicator lamps according to programmed logic.
It converts PLC commands into electrical switching signals, enabling automated equipment operation, process control, and sequence management.
2. How does the TSXDSZ08T2 Discrete Output Module operate?
The TSXDSZ08T2 receives output commands from the PLC CPU through the system backplane.
The PLC processes the user application program and determines the required output status according to operating conditions.
The module then activates the transistor output circuits to switch connected devices.
This solid-state switching method provides fast response, stable operation, and suitability for industrial automation systems requiring frequent switching actions.
3. What types of devices can be connected to the TSXDSZ08T2?
The TSXDSZ08T2 can control various industrial field devices, including:
- Solenoid valves
- Relay coils
- Contactors
- Indicator lamps
- Alarm devices
- Small actuators
- Machine control interfaces
The module is commonly used in industrial control cabinets to connect PLC systems with external automation equipment.
4. How can TSXDSZ08T2 output faults be diagnosed?
When an output fault occurs, first check whether the PLC program is correctly generating the output command.
Use PLC programming software to monitor the output channel status and confirm that the module receives the correct control signal.
Then inspect field wiring, power connections, connected loads, and terminal conditions to identify possible electrical problems.
If wiring and external devices are normal, check PLC hardware configuration, module diagnostics, and system status information for further troubleshooting.
5. What installation precautions should be considered for the Schneider TSXDSZ08T2?
Before installation, disconnect the equipment power supply and follow proper industrial safety procedures.
The module should be installed in the correct Modicon TSX PLC rack position and securely connected to the system backplane.
Output wiring should be selected according to the connected load requirements, and signal cables should be separated from high-power cables to reduce interference.
After installation, configure the module in the PLC engineering software and test all output channels before commissioning.
6. What are the advantages of the TSXDSZ08T2 transistor output design?
The TSXDSZ08T2 uses solid-state transistor output technology, providing faster switching speed and higher operating frequency compared with mechanical relay outputs.
Because it does not use mechanical contacts, it reduces wear-related failures and improves long-term reliability.
The transistor output design is suitable for applications requiring rapid switching, repetitive operations, and continuous production processes.
It helps improve automation system response speed and overall control performance.
7. What should be checked if the TSXDSZ08T2 does not work properly?
If the module does not provide correct output signals, first confirm that it is properly installed and recognized by the PLC system.
Check PLC diagnostic information for module alarms, configuration errors, or communication problems.
Verify that the module configuration in the engineering software matches the actual installed hardware.
If the configuration is correct, inspect the PLC rack connection, power supply condition, and field output wiring.
A combination of software diagnostics and hardware inspection can quickly locate and resolve the problem.
8. How should the Schneider TSXDSZ08T2 be maintained for reliable operation?
Routine maintenance should include checking module status indicators, reviewing PLC diagnostic information, and verifying connected field equipment operation.
Maintenance personnel should regularly inspect output wiring, terminal connections, cable conditions, and external devices to prevent failures caused by loose connections or component aging.
For critical automation systems, periodic testing of output channels is recommended to ensure PLC commands are executed correctly.
Preventive maintenance, condition monitoring, and functional testing can improve the reliability of the TSXDSZ08T2 and ensure stable long-term operation of Modicon TSX control systems.
Schneider TSXDSZ08T2 Discrete Output Module is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.








