Technical Specifications
| Parameter | Specification |
|---|---|
| Model | DS200UPLAG1BEA |
| Brand | GE |
| Product Type | LAN Power Supply Board |
| Product Series | Mark V |
| Main Function | LAN and operator interface power supply |
| Input Voltage | 115/230 VAC |
| Input Frequency | 50/60 Hz |
| DC Outputs | +24 V DC and +5 V DC |
| Primary Application | GE industrial control systems |
| System Function | Regulated power supply for control and interface circuits |
| Communication Interface | DLAN+ interface |
| Serial Interface | RS-232C |
| Configuration | DIP switches and hardware jumpers |
| Memory | Flash memory |
| Protection / Monitoring | Power-on reset and 5 V undervoltage detection |
| Typical Application | Turbine control, excitation control and industrial automation |
| Installation | GE control system cabinet |
| Dimensions | 220 × 100 × 30 mm |
| Weight | 1.45 kg |
FAQ
1. What is the GE DS200UPLAG1BEA used for?
The GE DS200UPLAG1BEA is a LAN Power Supply Board designed for GE industrial control equipment. Its primary function is to provide regulated DC power for operator interface and LAN-related circuits. The board accepts AC input and provides regulated +24 V DC and +5 V DC outputs required by associated control electronics. It also includes control and communication-related circuitry that allows it to operate as part of the larger GE control architecture. In an industrial installation, stable operation of this board is important because inadequate or unstable power can affect communication interfaces, operator interface modules, and other connected control components.
2. What are the main power specifications of the DS200UPLAG1BEA?
The DS200UPLAG1BEA is designed for an AC input of 115/230 V at 50/60 Hz and provides regulated +24 V DC and +5 V DC outputs. These DC voltage levels are intended to supply associated control and operator interface electronics. When troubleshooting the board, technicians should verify the incoming AC supply first and then check the relevant DC outputs using appropriate test equipment. Voltage measurements should always be performed according to the equipment’s approved maintenance procedure. An abnormal input condition can cause incorrect output voltage and may lead to secondary faults in connected control electronics.
3. What are the common symptoms of a faulty DS200UPLAG1BEA?
A faulty DS200UPLAG1BEA may cause loss of power to associated operator interface modules, LAN-related communication problems, controller alarms, intermittent system operation, or failure of connected electronics to initialize correctly. A complete power supply failure may result in multiple related devices becoming unavailable at the same time. Intermittent faults can be more difficult to identify and may appear as repeated resets, unstable communication, or sporadic loss of control functions. However, these symptoms can also be caused by external wiring, input power problems, downstream loads, or another control board. Troubleshooting should therefore begin with the complete power path rather than immediately replacing the board.
4. How should the DS200UPLAG1BEA be tested when the system has a power problem?
Start by confirming that the incoming AC supply is present and within the required operating range. Next, inspect the board’s connectors, wiring, and visible components for loose connections, overheating, contamination, or physical damage. The +24 V DC and +5 V DC outputs should then be measured using suitable electrical test equipment and the appropriate safety procedures. If the input voltage is correct but one or both DC outputs are abnormal, the board’s internal power supply circuitry should be investigated. It is also important to check whether an excessive downstream load is pulling the output voltage down, because an external short circuit or overloaded circuit can produce symptoms that resemble an internal power supply failure.
5. What communication interfaces are associated with the DS200UPLAG1BEA?
The DS200UPLAG1BEA includes a DLAN+ interface and an RS-232C serial interface as part of its system-level communication functions. These interfaces allow the board to interact with associated control and operator interface components. When communication problems occur, technicians should check both the electrical power supplied by the board and the physical communication connections. A communication failure does not necessarily indicate a damaged communication interface. Unstable power, incorrect cable connections, external equipment faults, or configuration problems can produce similar symptoms. A systematic check of power, connectors, communication cables, and connected equipment is recommended.
6. What is the function of the configuration switches and jumpers on the DS200UPLAG1BEA?
The DS200UPLAG1BEA uses hardware configuration elements, including DIP switches and jumpers, to support system-specific configuration and operating requirements. These settings can determine how the board interacts with the associated control architecture. The correct configuration depends on the specific equipment in which the board is installed. Technicians should therefore record the original switch and jumper positions before removing a board and compare them with the replacement board. Configuration settings should not be changed randomly during troubleshooting because an incorrect setting can introduce additional communication or control problems and make the original fault more difficult to identify.
7. Can an external load cause the DS200UPLAG1BEA to appear faulty?
Yes. A downstream short circuit, excessive load, damaged cable, or defective connected module can cause the output voltage to drop or become unstable. In such cases, the DS200UPLAG1BEA may appear to have an internal power supply fault even though the actual problem is located elsewhere in the system. When an abnormal DC output is detected, technicians should check both the board and the circuits supplied by that output. If the output returns to normal after the external load is isolated according to an approved maintenance procedure, the downstream circuit should be investigated further. This approach can prevent unnecessary replacement of an otherwise functional power supply board.
8. What precautions should be taken when replacing the DS200UPLAG1BEA?
Before replacing the DS200UPLAG1BEA, verify the complete part number and revision information against the installed control system. The equipment should be placed in the approved maintenance state, and all applicable electrical isolation and lockout/tagout procedures should be followed. Because the board works with AC input power, technicians must verify that hazardous voltage has been removed before handling the assembly. All cables and connectors should be clearly identified before removal, and the original DIP switch and jumper configuration should be documented. After installing the replacement board, check all connections carefully before restoring power. The +24 V and +5 V outputs, communication interfaces, operator interface functions, and associated control equipment should then be checked to confirm stable operation.
GE DS200UPLAG1BEA LAN Power Supply Board is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.