Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

Bently Nevada 3500/60-03-00 133835-01 Internal Terminals Of The TC Isolated I/O Module

  • Manufacturer: Bently Nevada
  • Product Number: 3500/60-03-00 133835-01
  • Condition: New & In Stock
  • Product Type: Internal Terminals Of The TC Isolated I/O Module
  • Origin: USA
  • Payment Methods: T/T, Western Union
  • Dimensions: 241.3 x 24.4 x 99.1 mm
  • Weight: 0.45 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model 3500/60-03-00
Part Number 133835-01
Product Type TC Isolated I/O Module with Internal Terminations
Product Series 3500 Machinery Protection System
Compatible Monitor 3500/60 Temperature Monitor
Input Type Thermocouple (TC)
Number of Channels 6 channels
Temperature Monitoring Supported
Channel Isolation Isolated thermocouple input channels
Isolation Voltage 250 VDC channel-to-channel
Temperature Input Thermocouple signals
Signal Conditioning Thermocouple input signal conditioning
Temperature Alarm Supported through the 3500/60 Temperature Monitor
Configuration Configurable through 3500 Rack Configuration Software
Termination Type Internal Terminations
Recorder Output Not supported
I/O Module Application 3500/60 temperature monitoring
Supported Sensor Type Thermocouples
Channel Configuration Individual temperature channels
Line Noise Rejection 50 Hz / 60 Hz selectable through system configuration
Cold Junction Compensation Supported
Typical Power Consumption Approximately 7 W
Operating Temperature -30°C to +65°C
Storage Temperature -40°C to +85°C
Relative Humidity Up to 95%, non-condensing
Rack Installation Bently Nevada 3500 Rack
Rack Space One full-height rear I/O position
Field Wiring Direct connection to internal terminal blocks
Typical Applications Turbines, compressors, generators, pumps and industrial process temperature monitoring
Dimensions 241.3 × 24.4 × 99.1 mm
Weight 0.45 kg

FAQ

1. What is the main function of the Bently Nevada 3500/60-03-00 133835-01?

The Bently Nevada 3500/60-03-00 133835-01 is an isolated thermocouple I/O module designed for the 3500/60 Temperature Monitor. It receives temperature signals from thermocouples and provides the necessary signal conditioning before the measurements are processed by the temperature monitoring system. The module provides six thermocouple input channels and uses isolated inputs to reduce the influence of electrical interference and potential differences between channels. It is mainly used for temperature monitoring on rotating machinery and industrial equipment, including turbines, compressors, generators, pumps and other process equipment. The internal termination configuration allows field wiring to be connected directly to the I/O module without requiring a separate external termination block.

2. How many thermocouple channels does the 133835-01 support?

The 133835-01 provides six independent thermocouple input channels for the 3500/60 Temperature Monitor. Each channel can be connected to a compatible thermocouple and used to monitor an individual temperature measurement point. This allows several critical temperature locations to be monitored through one temperature monitoring system. During installation, each thermocouple should be connected to the correct channel and the channel configuration in the 3500 system should correspond to the actual field wiring. Incorrect channel assignment can result in the temperature from one physical measurement point being displayed under another channel. For commissioning, it is therefore important to verify both the physical terminal connections and the software configuration before relying on the measured temperature values.

3. What is the advantage of the isolated thermocouple input design?

The isolated thermocouple input design helps electrically separate the individual temperature measurement circuits and reduce the influence of unwanted voltage differences or electrical interference. This is particularly useful in industrial environments where thermocouple cables may run near motors, generators, variable-frequency drives, high-current conductors or other sources of electrical noise. The 133835-01 provides channel-to-channel isolation, helping maintain more reliable temperature measurements when different field sensors operate under different electrical conditions. Isolation can also reduce the possibility that a problem on one temperature input will directly affect other measurement channels. However, proper cable routing, grounding, shielding and thermocouple installation remain important because electrical isolation does not eliminate every possible source of measurement interference.

4. What type of sensors can be connected to the 133835-01?

The 133835-01 is specifically designed for thermocouple temperature inputs. The connected thermocouple must be compatible with the temperature range and configuration supported by the 3500/60 Temperature Monitor. During installation, technicians should verify the thermocouple type, polarity, extension cable type and terminal connections. Using the wrong thermocouple type or incorrect extension wire can introduce significant measurement errors because different thermocouple materials generate different voltage-versus-temperature characteristics. Polarity should also be checked carefully because reversed thermocouple wiring can cause abnormal temperature readings. When replacing a thermocouple, it is recommended to verify the sensor specification and channel configuration together rather than assuming that any thermocouple can be connected to the same input.

5. What should be checked if one temperature channel shows an abnormal reading?

If a single channel displays an abnormal temperature, troubleshooting should start with the field thermocouple and wiring. First inspect the thermocouple for physical damage, loose connections, corrosion or an open circuit. Check the polarity and terminal connections at the 133835-01, then inspect the extension cable for broken conductors or incorrect wiring. If the wiring appears correct, compare the affected channel with another known-good channel using an appropriate test method. The 3500/60 configuration should also be checked to ensure that the correct thermocouple type and measurement parameters are assigned to the channel. If the thermocouple and wiring are confirmed to be good but the channel continues to provide an abnormal value, the I/O module and associated 3500/60 Temperature Monitor should then be investigated.

6. Does the 133835-01 provide recorder outputs?

No. The 133835-01 is the internal-termination isolated thermocouple I/O module used with the 3500/60 Temperature Monitor, which is the version without individual recorder outputs. Its primary purpose is to receive and condition the six thermocouple input signals and pass the temperature information to the monitoring module. If an application requires individual analog recorder outputs for the temperature channels, the appropriate 3500/61 Temperature Monitor and corresponding I/O configuration should be considered instead. When replacing an existing module, technicians should therefore confirm whether the installed system requires recorder outputs before selecting the replacement I/O module.

7. How should the 133835-01 be wired and configured?

Because the 133835-01 uses internal terminations, the thermocouple field wiring is connected directly to the terminal connections associated with the six input channels. Each thermocouple should be connected to the correct positive and negative terminals according to its polarity and the applicable wiring arrangement. After the physical connections are completed, the 3500 Rack Configuration Software should be used to verify the temperature channel configuration. The selected thermocouple type, channel assignment, alarm settings and applicable line-noise rejection configuration should correspond to the actual field installation. Before putting the system into service, each channel should be checked against a known temperature reference or another suitable verification method. This helps identify reversed polarity, incorrect sensor type, wiring mistakes and configuration errors before the monitored equipment reaches normal operating conditions.

8. What should be checked after replacing a 3500/60 133835-01?

After replacing the 133835-01, the complete temperature measurement circuit should be inspected before returning the monitoring system to normal operation. First confirm that the replacement module is the correct isolated thermocouple I/O configuration with internal terminations. Then verify that all six field thermocouple connections are installed on the correct channels and that no wires are loose or incorrectly polarized. The 3500/60 Temperature Monitor configuration should also be checked to ensure that the thermocouple type and channel assignments match the actual field installation. Each active channel should be monitored to confirm that the measured temperature is stable and reasonable. If alarm setpoints are configured, they should also be reviewed to ensure that they have not been changed unintentionally during maintenance. Finally, compare the displayed values with an appropriate reference where possible and confirm that the complete temperature monitoring system is operating normally before the equipment is placed back into full service.

Bently Nevada 3500/60-03-00 133835-01 Internal Terminals Of The TC Isolated I/O Module is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996