Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

ABB V18345-2010460001 Valve Positioner

  • Manufacturer: ABB
  • Product Number: V18345-2010460001
  • Condition: New & In Stock
  • Product Type: Valve Positioner
  • Origin: Sweden (SE)
  • Payment Methods: T/T, Western Union
  • Dimensions: 168.5 × 101 × 114.5 mm
  • Weight: 1.7 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Manufacturer ABB
Model V18345-2010460001
Product Series TZIDC
Product Type Intelligent Electro-Pneumatic Valve Positioner
Main Function Automatic positioning and closed-loop control of pneumatic valves
Input Signal 4–20 mA, two-wire
Communication HART
Actuator Type Pneumatic actuator
Actuator Configuration Double-acting, fail-safe
Position Feedback Internal valve position feedback
Explosion Protection Without explosion protection
Housing Varnished aluminum
Enclosure Protection IP65 / NEMA 4X
Supply Pressure 1.4–6 bar
Maximum Output Pressure 6 bar / 90 psi
Mounting Linear and rotary actuator mounting
Linear Actuator Mounting DIN / IEC 534 / NAMUR
Rotary Actuator Mounting VDI / VDE 3845
Cable Connection 1/2-14 NPT
Pneumatic Connection 1/4-18 NPT
Local Operation Integrated display and operator panel
Parameter Configuration Local configuration and HART communication
Diagnostic Function Operating-status monitoring and fault diagnosis
Automatic Adjustment Automatic determination and adjustment of control parameters
Typical Applications Process control valves and pneumatic actuators
Typical Industries Power, chemical, petrochemical, oil and gas, and process automation
Dimensions 168.5 × 101 × 114.5 mm
Weight 1.7 kg

FAQ

1. What is the main function of the ABB V18345-2010460001 valve positioner?

The ABB V18345-2010460001 is an intelligent electro-pneumatic valve positioner designed for controlling pneumatic process valves. It receives a 4–20 mA command from the control system and regulates the pneumatic actuator so that the valve reaches the required position. The positioner continuously compares the commanded position with the actual valve position and automatically corrects deviations through closed-loop control. Its double-acting fail-safe configuration allows controlled movement of suitable pneumatic actuators in both directions. The unit is suitable for integration into industrial automation and process-control systems where accurate and repeatable valve positioning is required.

2. What input signal does the V18345-2010460001 use?

The V18345-2010460001 uses a 4–20 mA two-wire input signal. This makes it suitable for connection to common PLC, DCS and industrial instrumentation systems. The control system determines the required valve position by changing the current within the configured range, while the positioner converts the electrical command into pneumatic actuator movement. During commissioning, the complete current loop should be checked to ensure that the signal is stable and correctly scaled. If the input signal is incorrect or fluctuates significantly, the valve may move unexpectedly or fail to reach the required position. Signal verification should therefore be completed before changing the positioner’s internal control parameters.

3. Does the V18345-2010460001 support HART communication?

Yes. The V18345-2010460001 supports HART communication, allowing technicians to access configuration and diagnostic information through the communication interface. HART communication can be used to review operating parameters, identify abnormal conditions and make appropriate configuration adjustments. This is particularly useful during commissioning and maintenance because additional device information can be obtained without relying only on the local display. When a valve exhibits incorrect positioning, slow response or unstable operation, HART communication can help determine whether the problem is related to the input signal, configuration or positioner operation. The electrical loop should be checked before establishing communication to ensure stable communication conditions.

4. What type of actuator is suitable for the V18345-2010460001?

This model is configured for double-acting pneumatic actuators and can be used with suitable linear or rotary actuator applications. Linear actuator installations can use DIN / IEC 534 or NAMUR mounting arrangements, while rotary actuator installations can use VDI / VDE 3845 interfaces. Before installation, the actuator type, mechanical interface, valve travel and movement direction should be checked carefully. The two pneumatic outputs must be connected to the appropriate actuator chambers according to the actuator configuration. Incorrect pneumatic connections can cause reversed movement, incomplete travel or unstable positioning. The feedback mechanism must also be correctly installed so that the positioner can accurately determine the actual valve position throughout the operating range.

5. What should be checked if the valve does not follow the 4–20 mA command correctly?

First, verify the actual 4–20 mA input signal and compare it with the output generated by the PLC or DCS. Check the wiring and confirm that the signal remains stable across the operating range. Next, inspect the instrument-air supply and make sure that pressure is sufficient and stable. Because the positioner is configured for double-acting operation, both pneumatic outputs should be checked for correct connections, pressure response and possible leakage. The valve and actuator should then be inspected for mechanical problems such as excessive friction, sticking or restricted travel. If the external systems are functioning correctly, the positioner’s configuration, calibration and feedback system should be checked. HART diagnostics can provide additional information that helps identify the source of the positioning problem.

6. How should the V18345-2010460001 be commissioned?

Commissioning should begin with a mechanical inspection of the positioner, actuator and feedback linkage. Confirm that the positioner is firmly mounted and that the feedback mechanism moves smoothly throughout the actuator’s travel. The 4–20 mA input circuit should then be checked, followed by inspection of the instrument-air supply and both pneumatic output connections. After confirming that the actuator can move correctly, the positioner’s configuration can be checked through the local operating interface or HART communication. The actuator type, movement direction, travel parameters and control settings should match the actual installation. The valve should then be tested at several command points across the operating range. Actual valve movement should follow the control signal smoothly, without excessive oscillation, incomplete travel or significant positioning error.

7. What are common causes of unstable valve positioning?

Unstable valve positioning may be caused by fluctuations in the 4–20 mA signal, unstable instrument-air pressure, pneumatic leakage, actuator problems, valve friction or incorrect feedback installation. With a double-acting actuator, incorrect connection of either pneumatic output can also affect the valve’s response and stability. Mechanical resistance in the valve or actuator may cause the positioner to repeatedly correct the position because the actual valve position does not respond as expected. If the electrical, pneumatic and mechanical systems are normal, the positioner’s calibration and control parameters should be reviewed. It is recommended to verify the physical conditions first rather than immediately modifying control parameters. HART diagnostic information can be used to further examine operating conditions and help identify the actual cause of instability.

8. What checks are required after replacing the V18345-2010460001?

After replacement, the complete valve-control loop should be inspected before returning the equipment to automatic operation. First confirm the model and configuration, then check the mechanical mounting and feedback mechanism. Verify the 4–20 mA input wiring and make sure the control system provides a stable signal. The pneumatic connections should be carefully inspected because the double-acting configuration requires correct connection of both actuator outputs. The actuator movement direction should then be tested to ensure that it corresponds with the process-control command. Check the configured input range, travel settings and other relevant parameters, and perform the required calibration. Test the valve at multiple control points and compare the commanded position with the actual position. Finally, check the diagnostic status and control-system feedback to ensure that there are no persistent alarms, communication faults or abnormal positioning conditions.

ABB V18345-2010460001 Valve Positioner is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996