Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

ABB V18345-2010521001 Valve Positioner

  • Manufacturer: ABB
  • Product Number: V18345-2010521001
  • Condition: New & In Stock
  • Product Type: Valve Positioner
  • Origin: Sweden (SE)
  • Payment Methods: T/T, Western Union
  • Dimensions: 168.5 × 101 × 114.5 mm
  • Weight: 1.7 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Manufacturer ABB
Model V18345-2010521001
Product Series TZIDC
Product Type Intelligent Electro-Pneumatic Valve Positioner
Main Function Automatic positioning and closed-loop control of pneumatic control valves
Input Signal 4–20 mA, two-wire
Communication HART
Actuator Type Pneumatic actuator
Actuator Configuration Double-acting
Position Feedback Internal valve position feedback
Fail-Safe Function Fail-safe operation
Supply Pressure 1.4–6 bar
Maximum Output Pressure 6 bar / 90 psi
Housing Material Varnished aluminum
Enclosure Protection IP65 / NEMA 4X
Mounting Linear and rotary actuator mounting
Linear Actuator Mounting DIN / IEC 534 / NAMUR
Rotary Actuator Mounting VDI / VDE 3845
Cable Connection 1/2-14 NPT
Pneumatic Connection 1/4-18 NPT
Local Operation Integrated display and operator panel
Configuration Local configuration and HART communication
Diagnostic Function Operating-status monitoring and fault diagnosis
Automatic Adjustment Automatic determination and adjustment of control parameters
Control Method Closed-loop position control
Typical Applications Process control valves and pneumatic actuators
Typical Industries Power, chemical, petrochemical, oil and gas, and process automation
Dimensions 168.5 × 101 × 114.5 mm
Weight 1.7 kg

FAQ

1. What is the main function of the ABB V18345-2010521001 valve positioner?

The ABB V18345-2010521001 is an intelligent electro-pneumatic valve positioner designed to control the position of pneumatic process valves. It receives a 4–20 mA command from a PLC, DCS or other process control system and converts this electrical signal into the appropriate pneumatic actuator movement. The positioner continuously compares the requested valve position with the actual position and automatically corrects any deviation. This closed-loop control method helps maintain accurate valve positioning even when process conditions change. The double-acting configuration allows the device to control suitable pneumatic actuators in both directions, making it suitable for a wide range of industrial process-control applications.

2. What type of input signal does the V18345-2010521001 use?

The V18345-2010521001 uses a 4–20 mA two-wire input signal. This is a standard industrial analog signal that can be connected to PLC, DCS and other process automation systems. The control system uses the current value to represent the required valve position, while the positioner interprets the signal and controls the pneumatic actuator accordingly. During commissioning, technicians should verify the complete current loop and confirm that the signal is stable throughout the operating range. Incorrect scaling, unstable current, wiring problems or poor loop connections can cause positioning errors. Checking the actual input current before adjusting the positioner’s configuration is therefore an important commissioning and troubleshooting step.

3. Does the V18345-2010521001 support HART communication?

Yes. The V18345-2010521001 supports HART communication, which provides digital access to configuration, operating and diagnostic information. HART can be used during commissioning to review device parameters and verify the operating status of the positioner. It is also useful for maintenance because technicians can obtain additional diagnostic information when the valve does not respond correctly to the control signal. For example, abnormal positioning, slow response or repeated position corrections can be investigated through the available device information. Before using HART communication, the electrical loop should be checked to ensure that the positioner has a stable and correctly connected control circuit.

4. What type of pneumatic actuator is compatible with the V18345-2010521001?

The V18345-2010521001 is configured for double-acting pneumatic actuators and can be used with suitable linear or rotary actuator applications. Linear actuator installations can use DIN / IEC 534 or NAMUR mounting arrangements, while rotary actuator installations can use VDI / VDE 3845 mounting interfaces. Before installation, the actuator’s mechanical interface, required travel, movement direction and feedback mechanism should be verified. Both pneumatic output connections must be connected correctly to the corresponding actuator chambers. If the pneumatic lines are reversed or incorrectly connected, the valve may move in the wrong direction or fail to achieve stable positioning. Proper feedback installation is also essential because the positioner relies on actual valve-position information for closed-loop control.

5. What should be checked when the valve does not reach the commanded position?

Troubleshooting should start with the 4–20 mA input signal. Measure the current at the positioner and verify that it corresponds to the command from the PLC or DCS. The instrument-air supply should then be checked to ensure that pressure is stable and sufficient for the actuator. Because this is a double-acting configuration, both pneumatic output paths should be inspected for correct connection, leakage and pressure response. The valve and actuator should also be checked for mechanical problems such as excessive friction, sticking, restricted travel or damaged components. If the external systems are functioning normally, check the position feedback mechanism and the positioner’s configuration and calibration. HART communication can provide additional diagnostic information to help determine whether the problem originates from the control signal, pneumatic system, actuator, valve or positioner.

6. How should the ABB V18345-2010521001 be commissioned?

Commissioning should begin by checking the mechanical installation and confirming that the positioner is firmly attached to the pneumatic actuator. The feedback mechanism should move smoothly with the actuator and should not have excessive mechanical play. Next, verify the 4–20 mA electrical loop and the instrument-air supply. Both pneumatic outputs should be connected correctly for the double-acting actuator configuration. After the basic connections have been verified, configure the positioner through the local interface or HART communication. The actuator type, movement direction, valve travel and other control parameters should correspond to the actual installation. The valve should then be operated at several control points to confirm that the actual position follows the requested position accurately. Any abnormal oscillation, slow response or incomplete travel should be investigated before the valve is placed into normal automatic operation.

7. What are the common causes of unstable valve positioning?

Unstable valve positioning can be caused by problems with the electrical signal, pneumatic supply, actuator, valve mechanism, feedback system or positioner configuration. A fluctuating 4–20 mA signal can cause continuous position corrections because the requested valve position is constantly changing. Insufficient or unstable instrument-air pressure can also cause inconsistent actuator movement. Mechanical problems such as valve-stem friction, sticking, actuator wear or incorrect feedback installation may prevent the valve from responding smoothly. For double-acting actuators, incorrect pneumatic connections can further affect movement and stability. If these physical conditions are normal, the positioner’s calibration and control parameters should be reviewed. HART diagnostics can assist in identifying abnormal operating conditions and provide additional information for systematic troubleshooting.

8. What checks should be performed after replacing the V18345-2010521001?

After replacing the positioner, the complete control loop should be checked before returning the valve to automatic service. First verify the model and configuration, then inspect the mechanical mounting and feedback linkage. Check the 4–20 mA wiring and confirm that the control system provides a stable input signal. Because the positioner uses a double-acting configuration, both pneumatic outputs must be checked carefully to ensure that they are connected to the correct actuator chambers. Test the actuator movement direction and confirm that it corresponds with the control-system command. The input range, travel settings, actuator configuration and other relevant parameters should then be reviewed and calibrated as required. Test the valve at multiple command points and compare the requested position with the actual position. Finally, check diagnostic information and control-system feedback for persistent alarms, communication problems or abnormal positioning behavior before returning the equipment to continuous process operation.

ABB V18345-2010521001 Valve Positioner is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996