Technical Specifications
| Parameter | Specification |
|---|---|
| Model | ATS48C32Q |
| Product Type | Soft Starter |
| Product Series | Altistart 48 |
| Manufacturer | Schneider Electric |
| Application | Three-phase asynchronous motors |
| Main Applications | Heavy-duty industrial equipment, pumps and ventilation systems |
| Utilization Category | AC-53A |
| Rated Supply Voltage | 230–415 VAC |
| Supply Voltage Tolerance | -15% to +10% |
| Supply Voltage Range | 195–456 VAC |
| Supply Frequency | 50–60 Hz |
| Permitted Frequency Range | 47.5–63 Hz |
| Rated Current, Line Connection | 320 A |
| Rated Current, Delta Connection | 554 A |
| Starting Method | Torque-controlled starting |
| Starting Current Limitation | Approximately 5 × motor rated current |
| Motor Power at 230 V, Line Connection | 75 kW severe duty / 90 kW standard duty |
| Motor Power at 230 V, Delta Connection | 132 kW severe duty / 160 kW standard duty |
| Motor Power at 400 V, Line Connection | 132 kW severe duty / 160 kW standard duty |
| Motor Power at 400 V, Delta Connection | 220 kW severe duty / 250 kW standard duty |
| Power Dissipation | Approximately 695 W severe duty / 902 W standard duty |
| Control Circuit Voltage | 220–415 VAC, 50/60 Hz |
| Control Circuit Consumption | Approximately 50 W |
| Digital Inputs | 5 |
| Digital Input Type | Logic and PTC inputs |
| Digital Input Voltage | 24 VDC, maximum 30 VDC |
| Outputs | 2 |
| Relay Outputs | Fault, end of starting and motor-powered status |
| Logic Outputs | 2 configurable outputs |
| Analog Output | 0–20 mA / 4–20 mA |
| Analog Output Load | Maximum 500 Ω |
| Communication Protocol | Modbus |
| Communication Interface | RS-485 |
| Communication Connector | RJ45 |
| Communication Speed | 4800 / 9600 / 19200 bps |
| Maximum Network Devices | 31 |
| Bypass Function | External bypass supported |
| Cooling Method | Forced-air cooling |
| Protection Rating | IP00 |
| Mounting Position | Vertical, ±10° |
| Construction | Heatsink-equipped |
| Applicable Standard | EN/IEC 60947-4-2 |
| Operating Temperature | -10 to +40°C without derating; derating required from +40 to +60°C |
| Maximum Installation Altitude | 1000 m without derating |
| Relative Humidity | 0–95%, non-condensing |
| Typical Applications | Pumps, fans, compressors, conveyors and heavy-duty industrial machinery |
| Dimensions | 380 × 320 × 265 mm |
| Weight | 18.2 kg |
FAQ
1. What is the main purpose of the Schneider ATS48C32Q soft starter?
The ATS48C32Q is a high-current soft starter from the Schneider Electric Altistart 48 series. It is designed to control the starting and stopping of three-phase asynchronous motors. The unit uses torque-controlled starting to gradually accelerate the motor instead of applying full line voltage immediately. This reduces electrical stress during startup and helps minimize mechanical shock transmitted to couplings, gearboxes, belts, pumps, and other drive components. The ATS48C32Q is particularly suitable for large pumps, fans, compressors, conveyors, and heavy industrial machinery where direct starting can produce excessive current or mechanical stress. Integrated motor thermal protection, starter protection, and phase-loss detection provide additional operational protection.
2. What motor power range is suitable for the ATS48C32Q?
The applicable motor power depends on supply voltage, motor connection method, and whether the application is standard duty or severe duty. At 400 V with line connection, the ATS48C32Q can be used for approximately 160 kW in standard-duty applications and approximately 132 kW in severe-duty applications. When connected to the motor delta terminals, the applicable rating can reach approximately 250 kW for standard duty and 220 kW for severe duty. At 230 V, the line-connected ratings are approximately 90 kW for standard duty and 75 kW for severe duty, while delta connection supports approximately 160 kW and 132 kW respectively. Actual selection should always consider motor rated current, starting time, load inertia, starting frequency, and operating duty rather than relying on motor power alone.
3. What supply voltage and frequency does the ATS48C32Q support?
The ATS48C32Q is designed for three-phase AC supplies from 230 to 415 VAC, with a supply voltage tolerance of approximately -15% to +10%. Its normal operating frequency is 50–60 Hz, with a permitted frequency range of approximately 47.5–63 Hz. Before commissioning, the actual incoming three-phase voltage should be measured and compared with the soft starter and motor requirements. The motor connection must also be compatible with the selected supply voltage. Phase loss, abnormal voltage, or incorrect motor wiring can result in insufficient starting torque, excessive current, overheating, or protective trips. Proper verification of the incoming supply is therefore an important part of commissioning.
4. What is the rated current of the ATS48C32Q?
The ATS48C32Q has a rated current of approximately 320 A when used with a line connection and up to approximately 554 A when connected to the motor delta terminals. The appropriate current rating also depends on whether the application is standard duty or severe duty. When selecting the soft starter, the motor nameplate current should be compared with the starter’s applicable current rating while also considering acceleration time, starting frequency, load inertia, ambient conditions, and the overall duty cycle. A motor that has an acceptable nominal current can still require a higher-capacity soft starter if it has a very high inertia, extended acceleration period, or frequent starting cycle.
5. What should be checked if the motor does not accelerate properly with an ATS48C32Q?
First, verify the three-phase input supply and confirm that all phases are present and within the required voltage range. Next, check the motor rated-current setting, main power wiring, motor connection method, and control inputs. If the motor is connected through its delta terminals, the complete power connection should be carefully verified. If the electrical installation is correct, inspect the mechanical load for blocked pumps, seized bearings, excessive friction, overloaded conveyors, or excessive load inertia. The starting current limitation and torque-control parameters should also be checked. If the current limit is set too low, the motor may not develop enough torque to accelerate the load. An unusually long acceleration period can indicate either insufficient starting torque or excessive mechanical resistance.
6. What are the common causes of an ATS48C32Q starting fault?
Starting faults can be associated with phase loss, abnormal supply voltage, motor overload, incorrect parameter settings, excessive mechanical load, or excessive acceleration time. When a fault occurs, the first step should be to identify the actual diagnostic condition before changing any settings. The three-phase supply, motor nameplate current, motor wiring, and connection method should then be checked. High-inertia equipment requires particular attention because the motor may remain at elevated current for an extended period during acceleration, increasing thermal stress. Mechanical problems such as blocked pumps, damaged bearings, or jammed transmission components can produce similar symptoms. Simply increasing protection thresholds without identifying the root cause can expose both the motor and soft starter to unnecessary thermal stress.
7. How does the ATS48C32Q provide motor thermal protection?
The ATS48C32Q incorporates motor thermal protection and monitors the motor’s operating condition based on current and configured motor parameters. The motor rated-current setting should correspond to the actual value shown on the motor nameplate. If the configured value is too high, overload protection may not respond appropriately to an actual thermal overload. If it is too low, nuisance trips may occur during normal startup or operation. For severe-duty applications, the starting frequency, acceleration time, ambient temperature, motor cooling conditions, and continuous operating period should all be considered. Large motors that start frequently can accumulate heat over several operating cycles, so thermal protection should be evaluated against the complete duty cycle rather than a single start.
8. What should be checked when installing and commissioning an ATS48C32Q?
Before installation, verify the motor rated voltage, rated current, power, frequency, connection method, and load characteristics. The correct standard-duty or severe-duty rating should then be selected according to the actual application. The ATS48C32Q should be installed vertically with sufficient clearance for its forced-air cooling system. Before energizing the equipment, inspect the incoming power, control circuit, grounding, motor connections, and protective devices. During commissioning, verify the motor rated-current setting, starting torque, acceleration time, current limitation, and control inputs. If Modbus communication is used, the RS-485 wiring, communication address, and baud rate should also be checked. During the first startup, monitor motor current, acceleration behavior, fault status, and operating temperature. For high-inertia, heavy-duty, or frequently started equipment, the complete operating cycle should be evaluated to ensure that thermal loading remains within acceptable limits.
Schneider ATS48C32Q Soft Starter is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.