Schneider ATS48C48Q Soft Starter
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 15305023276 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | ATS48C48Q |
| Product Type | Soft Starter |
| Product Series | Altistart 48 |
| Manufacturer | Schneider Electric |
| Application | Three-phase asynchronous motors |
| Main Applications | Heavy-duty industrial machinery, pumps, fans, compressors and conveyors |
| Utilization Category | AC-53A |
| Rated Supply Voltage | 230–415 VAC |
| Supply Voltage Tolerance | -15% to +10% |
| Supply Frequency | 50–60 Hz |
| Rated Current | 437 A |
| Starting Method | Torque-controlled starting |
| Starting Current Limitation | Adjustable according to motor and load requirements |
| Motor Power at 230 V, Line Connection | Up to approximately 110 kW severe duty / 132 kW standard duty |
| Motor Power at 230 V, Delta Connection | Up to approximately 220 kW severe duty / 250 kW standard duty |
| Motor Power at 400 V, Line Connection | Up to approximately 220 kW severe duty / 250 kW standard duty |
| Motor Power at 400 V, Delta Connection | Up to approximately 315 kW severe duty / 355 kW standard duty |
| Motor Thermal Protection | Integrated |
| Soft Starter Thermal Protection | Integrated |
| Phase Protection | Line phase-loss detection |
| Control Circuit Voltage | 220–415 VAC, 50/60 Hz |
| Digital Inputs | 5 |
| Digital Input Voltage | 24 VDC |
| PTC Input | Supported |
| Logic Outputs | 2 configurable outputs |
| Relay Outputs | Programmable relay outputs |
| Analog Output | 0–20 mA / 4–20 mA |
| Analog Output Load | Maximum 500 Ω |
| Communication Protocol | Modbus |
| Communication Interface | RS-485 |
| Communication Connector | RJ45 |
| Communication Speed | 4800 / 9600 / 19200 bps |
| External Bypass | Supported |
| Cooling Method | Forced-air cooling |
| Protection Rating | IP00 |
| Installation Position | Vertical installation |
| Applicable Standard | IEC/EN 60947-4-2 |
| Operating Temperature | -10 to +40°C without derating |
| Maximum Operating Temperature | Up to +60°C with appropriate derating |
| Typical Applications | Pumps, fans, compressors, conveyors and high-inertia machinery |
| Dimensions | 670 × 400 × 300 mm |
| Weight | 51.4 kg |
FAQ
1. What is the main function of the Schneider ATS48C48Q soft starter?
The ATS48C48Q is a high-power soft starter designed to control the starting and stopping of three-phase asynchronous motors. Instead of applying the full supply voltage to the motor immediately, it uses controlled starting to gradually build motor torque and accelerate the load. This helps reduce high starting current and mechanical shock. The ATS48C48Q is particularly suitable for heavy industrial machinery, pumps, compressors, fans, conveyors, and other applications where direct-on-line starting could place excessive stress on the electrical supply or mechanical transmission system.
2. What motor power range is suitable for the ATS48C48Q?
The ATS48C48Q is intended for large motor applications, with the actual power capability depending on supply voltage, motor connection, and application duty. At 400 V line connection, it can be used for motors up to approximately 250 kW in standard-duty applications and approximately 220 kW in severe-duty applications. With delta connection, the corresponding ratings can reach approximately 355 kW and 315 kW. At 230 V, the available power ratings are lower. When selecting the unit, motor rated current, starting time, load inertia, starting frequency, and thermal operating conditions should all be considered rather than selecting the soft starter based only on motor kW.
3. What power supply does the ATS48C48Q require?
The ATS48C48Q is designed for three-phase AC power from 230 to 415 VAC and operates at 50–60 Hz. The incoming supply should be checked carefully before commissioning to ensure that the voltage is within the permitted range and that all three phases are present. The motor’s rated voltage and connection method must also match the actual supply arrangement. Phase loss, significant voltage imbalance, or incorrect motor wiring can result in insufficient starting torque, excessive current, overheating, or protective shutdown.
4. How does the ATS48C48Q reduce motor starting stress?
The ATS48C48Q uses controlled torque starting to progressively accelerate the motor. This prevents the sudden current and torque increase normally associated with direct-on-line starting. Reducing the initial electrical and mechanical shock can help protect motor windings, couplings, shafts, gearboxes, belts, pumps, and other drive components. It can also reduce the impact of motor starting on the plant’s electrical distribution system. Correct adjustment of the starting parameters is important because the motor must still receive enough torque to overcome the connected load and reach normal operating speed within the required time.
5. What should be checked if the motor does not accelerate properly with an ATS48C48Q?
Start by checking the three-phase power supply and confirming that all phases are present and within the required voltage range. Next, verify the motor rated-current setting, main power wiring, motor connection, control signals, and protective devices. If the electrical system is correct, inspect the mechanical load for excessive inertia, blocked pumps, seized bearings, overloaded conveyors, or abnormal friction. The current limitation and starting parameters should also be reviewed. If the current limit is too low, the motor may not develop enough torque to accelerate the load. An unusually long acceleration period can indicate either insufficient starting torque or an excessive mechanical load.
6. What are the common causes of an ATS48C48Q trip during startup?
A startup trip may be caused by phase loss, abnormal supply voltage, motor overload, incorrect motor-current settings, excessive mechanical load, excessive acceleration time, or unsuitable starting parameters. High-inertia equipment can place significant thermal stress on the motor and soft starter because the motor may remain at elevated current for an extended period. Mechanical problems such as blocked pumps, damaged bearings, jammed conveyors, or transmission problems can also cause excessive current. When a fault occurs, the fault indication should be identified first, followed by systematic inspection of the power supply, motor settings, wiring, and mechanical load.
7. How should the motor thermal protection be configured on the ATS48C48Q?
The motor-current setting should correspond to the actual rated current shown on the motor nameplate. This value is important for the soft starter’s motor thermal monitoring and protection functions. If the configured current is too high, the motor may not receive adequate protection during an overload. If it is too low, nuisance trips may occur during normal operation. For heavy-duty applications, the complete operating cycle should be evaluated, including acceleration time, number of starts per hour, ambient temperature, motor cooling, load level, and continuous running time. Repeated starting can cause heat accumulation even when individual starts appear normal.
8. What should be checked before installing and commissioning an ATS48C48Q?
Before installation, confirm the motor rated voltage, rated current, power, frequency, connection method, and mechanical load characteristics. The ATS48C48Q should be correctly selected for the required standard-duty or severe-duty application. Check the incoming three-phase supply, control circuit, grounding, motor wiring, protective devices, and emergency-stop circuit before energizing the system. Adequate ventilation should also be provided because the soft starter uses forced-air cooling. During commissioning, verify the motor-current setting, acceleration parameters, current limitation, control inputs, and protection functions. If Modbus communication is used, check the RS-485 wiring and communication parameters. During the first startup, monitor motor current, acceleration behavior, fault indications, and operating temperature to confirm that the motor and soft starter are operating correctly.
Schneider ATS48C48Q Soft Starter is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.