Allen Bradley 20BC105A3ANNANA0 PowerFlex 700 AC Drive
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 15305023276 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Model | 20BC105A3ANNANA0 |
| Product Series | PowerFlex 700 |
| Product Type | AC Drive |
| Rated Input Voltage | 400 VAC |
| Input Voltage Range | 380–480 VAC |
| Input Phase | 3-phase |
| Rated Input Frequency | 50 Hz |
| Input Frequency Tolerance | 47 Hz |
| Rated Output Current | 105 A |
| Normal Duty Power Rating | 55 kW |
| Output Phase | 3-phase |
| Maximum Output Frequency | 400 Hz |
| Control Type | Standard Control |
| Digital Inputs | 6 |
| Digital Outputs | 3 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
| I/O Configuration | Standard 24V AC/DC I/O |
| Internal Communication Module | No Communication Module |
| Feedback | No Feedback |
| Human Interface | Full LCD Keypad |
| Brake Resistor | No Internal Brake Resistor |
| EMC Filter | EMC Filter with Common-Mode Choke |
| Enclosure Rating | IP20 / NEMA Type 1 |
| Efficiency | 97.5% at rated current and nominal line voltage |
| Input Voltage Tolerance | ±10% |
| Maximum Altitude | 1000 m without derating |
| Operating Temperature | Up to 50°C at 400 VAC |
| Storage Temperature | -40°C |
| Relative Humidity | 5–95%, non-condensing |
| Shock Resistance | 15 G peak for 11 ms |
| Vibration Resistance | 0.152 mm displacement, 1 G peak |
| Supported Communication Options | DeviceNet, EtherNet/IP, LON, TCP/IP, PROFIBUS, CAN, Modbus |
| Dimensions | 689.6 × 308.9 × 275.4 mm |
| Weight | 37.19 kg |
FAQ
1. What is the rated output current and power rating of the 20BC105A3ANNANA0?
The 20BC105A3ANNANA0 is a PowerFlex 700 AC drive with a rated output current of 105 A and a normal-duty power rating of 55 kW. It is designed for three-phase industrial motor control and can be used for applications such as conveyors, pumps, fans, compressors, material handling equipment, and production machinery. When selecting the drive for a motor, the motor nameplate current should be checked against the drive’s rated output current. The actual load profile should also be considered, particularly for equipment with high starting torque, frequent acceleration and deceleration, continuous operation, or significant load fluctuations.
2. What input power supply is required for this PowerFlex 700 drive?
The 20BC105A3ANNANA0 is designed for a three-phase 400 VAC power supply and supports a 380–480 VAC input voltage range. The rated input frequency is 50 Hz. Before commissioning, the incoming voltage should be measured and the three-phase power supply should be checked for excessive voltage imbalance. The upstream circuit protection, disconnect device, grounding system, and power cables should be appropriately selected for the drive’s electrical rating. Stable input power is important for reliable operation because significant voltage fluctuations or abnormal line conditions can result in undervoltage, overvoltage, excessive heating, or protective shutdowns.
3. What type of motor applications can the 20BC105A3ANNANA0 control?
The drive is suitable for a wide range of three-phase AC motor applications where adjustable-speed operation is required. Typical applications include industrial conveyors, pumps, ventilation systems, compressors, processing machinery, material-handling equipment, and automated production lines. The drive can regulate motor speed by adjusting output frequency and voltage while providing controlled acceleration and deceleration. For high-inertia machinery or applications involving frequent starts and stops, the acceleration and deceleration parameters should be selected according to the mechanical characteristics of the equipment. Motor current, load torque, operating cycle, and thermal requirements should also be evaluated before final commissioning.
4. Does the 20BC105A3ANNANA0 include an internal communication module?
This configuration does not include an internal communication module. The PowerFlex 700 platform supports several communication options, including DeviceNet, EtherNet/IP, LON, TCP/IP, PROFIBUS, CAN, and Modbus, but the required communication hardware must be selected according to the automation system and drive configuration. If the drive is being integrated with a PLC, DCS, or SCADA system, the communication option, command source, speed reference source, and required data mapping should be confirmed before installation. For replacement projects, the communication architecture of the existing drive should be compared with the replacement unit to ensure that the required network functions can be maintained.
5. Does the 20BC105A3ANNANA0 have an internal braking resistor?
The 20BC105A3ANNANA0 does not include an internal braking resistor. This is important for applications involving high-inertia loads or frequent rapid deceleration. During motor deceleration, mechanical energy can be regenerated into the drive’s DC bus, increasing the DC-bus voltage. If the regenerated energy becomes excessive, the drive may experience a DC-bus overvoltage condition. For applications such as high-inertia conveyors, lifting machinery, centrifuges, or equipment with frequent stopping cycles, the braking requirements should be evaluated during system design. If rapid deceleration is required, an appropriate external braking solution may be necessary based on load inertia, deceleration time, braking frequency, and regenerated energy.
6. How should an overcurrent fault on the 20BC105A3ANNANA0 be troubleshot?
The first step is to identify when the overcurrent fault occurs. If it appears during startup or acceleration, the acceleration time may be too short for the mechanical load. High-inertia equipment requires greater torque during acceleration, and an aggressive acceleration ramp can cause the motor current to rise rapidly. If the fault occurs during normal operation, inspect the driven machinery for excessive load, mechanical blockage, bearing problems, increased friction, or abnormal process conditions. The motor cable should also be checked for phase-to-phase shorts, ground faults, insulation damage, and incorrect connections. Motor nameplate data stored in the drive should be verified as well. If the mechanical system, wiring, and parameters are normal but the fault remains, the motor and drive output power section should be examined further.
7. What can cause a DC-bus overvoltage fault on the 20BC105A3ANNANA0?
A DC-bus overvoltage fault can occur when excessive regenerative energy is returned to the drive during motor deceleration. This is particularly common with high-inertia loads, short deceleration times, or applications that repeatedly accelerate and decelerate. When the motor slows down, it can temporarily act as a generator and feed mechanical energy back into the drive, causing the DC-bus voltage to increase. The input power supply should also be checked to ensure that the incoming voltage is within the permitted range. Increasing the deceleration time can reduce regenerative stress. If the machine requires rapid stopping and extending the deceleration time is not practical, the application should be evaluated for an external braking solution capable of dissipating the required regenerative energy.
8. What maintenance should be performed on the 20BC105A3ANNANA0?
Regular maintenance should focus on cooling, electrical connections, environmental conditions, and stored fault information. The ventilation paths should be inspected and cleaned periodically to prevent dust accumulation from restricting airflow and increasing internal temperatures. Electrical connections, including input terminals, output terminals, motor cables, grounding points, and control wiring, should be checked for signs of loosening, overheating, or damage. The installation environment should be maintained within the specified temperature and humidity limits, and exposure to conductive dust, excessive moisture, and corrosive substances should be minimized. Reviewing the drive’s fault history during scheduled maintenance is also recommended. Repeated overcurrent, overvoltage, overtemperature, or communication faults should be investigated systematically because recurring alarms may indicate an underlying issue with the motor, mechanical load, power supply, cooling system, or drive configuration.
Allen Bradley 20BC105A3ANNANA0 PowerFlex 700 AC Drive is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.