GE IS200EXAMG1A Exciter Attenuation Module

  • Manufacturer: GE
  • Product Number: IS200EXAMG1A
  • Condition: New & In Stock
  • Product Type: Exciter Attenuation Module
  • Origin: USA
  • Payment Methods: T/T, Western Union
  • Dimensions: 230 x 191 x 30 mm
  • Weight: 0.46 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Model IS200EXAMG1A
Product Type Exciter Attenuation Module
Product Series EX2100 Excitation Control System
Manufacturer GE
Module Designation EXAM
Primary Function Attenuates and monitors high voltage from the exciter bridge and provides signals for ground detection
Main Application EX2100 excitation system ground detection
Associated Module IS200EGDM Exciter Ground Detector Module
Associated Backplane IS200EPBP Exciter Power Backplane
Installation Location High Voltage Interface (HVI) module in the auxiliary cabinet
System Configuration Supports Simplex and TMR configurations
Typical Quantity per System 1 module
DC Bus Voltage Approximately 125 to 750 VDC, depending on system configuration
AC Line-to-Line Voltage Approximately 120 to 1000 VAC RMS, depending on system configuration
Maximum AC Input Frequency 480 Hz
Ground Detection Supports exciter field ground detection
Ground Test Signal ±50 V square-wave test signal
Ground Test Duration Up to approximately 10 seconds
Fault Response Provides ground fault detection for protective shutdown functions
Attenuation Resistors RA1, RA2, RA3, RA4
Detection Resistors Rx, Ry, Rz
Relay Coil 24 VDC
Relay Coil Current Less than 20 mA
Relay Default State De-energized
Relay Function Ground test activation and M1/M2 control channel selection
Main Interfaces J1, J2, E1, E2, TB1
J2 Connector 9-pin D-type connector for test signals, relay control, and leakage-current-related signals
J1 Connector 3-pin locking connector for exciter relay auxiliary contacts
E1 Connection Vbus-P field bus voltage connection
E2 Connection Vbus-N field bus voltage connection
TB1 Function EXAM shield ground connection to cabinet frame ground
Jumpers JP1, JP2, JP3
Filter Capacitor Selection Jumper-selectable filtering according to PPT voltage range
Fuses None
LED Indicators None
Test Points None
Independent Processor None
Typical Application Generator excitation system field ground detection and protection
Mounting Location HVI module within the auxiliary cabinet
Maintenance No routine adjustment required; jumper configuration must match the system design
Dimensions 230 × 191 × 30 mm
Weight 0.46 kg

FAQ

1. What is the main function of the GE IS200EXAMG1A?

The IS200EXAMG1A is an Exciter Attenuation Module used in the GE EX2100 excitation control system. Its primary function is to work with the excitation system ground detection circuitry by attenuating and monitoring the relatively high voltage present on the exciter bridge and providing suitable signals to the ground detection system. The module is installed in the High Voltage Interface section of the auxiliary cabinet and works together with the IS200EGDM Exciter Ground Detector Module. The EXAM contains attenuation and detection resistors that form part of the electrical network used to monitor the exciter field circuit. During a ground detection test, the module allows the system to evaluate the electrical condition of the excitation circuit and determine whether an abnormal ground condition is present. If a serious field ground fault is detected, the associated protection logic can initiate the appropriate response to protect the excitation and generator system.

2. What is the relationship between the IS200EXAMG1A and IS200EGDM?

The IS200EXAMG1A and IS200EGDM are complementary components within the EX2100 excitation system ground detection arrangement. The EXAM provides the high-voltage attenuation and field-side interface circuitry, while the EGDM performs the associated ground detection and control functions. The EXAM uses attenuation resistors and detection resistors to create the electrical measurement path required for ground monitoring. The EGDM controls and evaluates the ground detection process using the signals provided through the EXAM and associated backplane connections. During troubleshooting, both modules should therefore be considered as part of the same functional circuit. A ground detection problem does not automatically indicate an EXAM failure. The EGDM, IS200EPBP backplane, field wiring, relay circuits, and the actual excitation field circuit should also be checked. Proper diagnosis requires identifying where the ground detection signal is lost or becomes abnormal.

3. Can the IS200EXAMG1A be used in both Simplex and TMR systems?

Yes. The IS200EXAMG1A can be used in EX2100 systems configured for both Simplex and TMR control architectures. In these applications, the module provides the required interface for the excitation ground detection function. A typical system uses one EXAM module, while the surrounding control architecture determines how the associated signals are processed and distributed. In TMR configurations, the relay circuitry on the EXAM can participate in selecting between M1 and M2 control channels. This allows the ground detection feedback to be associated with the appropriate control path according to the system configuration. When replacing an EXAM module in a TMR installation, technicians should verify the complete hardware configuration and jumper settings rather than assuming that every system uses identical wiring. After replacement, the ground detection function and the relevant redundant control paths should be tested to confirm that the system correctly recognizes both normal and fault conditions.

4. How does the IS200EXAMG1A perform exciter field ground detection?

The IS200EXAMG1A forms part of the electrical network used to perform controlled exciter field ground detection. During a ground test, a defined test signal is applied through the associated ground detection circuitry, while the attenuation and detection resistors within the EXAM provide the necessary interface between the high-voltage field circuit and the monitoring electronics. The system evaluates the resulting electrical response to determine whether the field circuit has an abnormal connection to ground. A serious ground condition changes the expected voltage and current relationships within the detection network and can therefore be recognized by the associated control circuitry. The ground test uses a controlled ±50 V square-wave signal and is limited in duration, with a typical maximum test period of approximately 10 seconds. This controlled approach allows the excitation system to check insulation and ground conditions without leaving the test circuit continuously active.

5. What are JP1, JP2, and JP3 used for on the IS200EXAMG1A?

JP1, JP2, and JP3 are configuration jumpers used to establish the appropriate electrical configuration of the IS200EXAMG1A for the particular EX2100 system. The jumper arrangement is important because EX2100 excitation systems can have different voltage conditions, and the attenuation and filtering network must be configured appropriately. JP1 and JP2 are associated with filter capacitor selection for different PPT voltage ranges, while JP3 is also part of the board’s configuration arrangement. The correct positions depend on the specific system design and should be verified using the applicable system documentation. When replacing an EXAM board, the original jumper positions should be recorded before removing the old board and then reproduced on the replacement. Changing jumper positions without confirming the required configuration can affect the ground detection circuit and may result in incorrect detection behavior, false alarms, or failure to detect an actual ground condition.

6. What are the J1, J2, E1, E2, and TB1 connections used for?

The IS200EXAMG1A uses several different connection points for control, field, and grounding functions. J2 is a 9-pin D-type connector that carries signals associated with the ground test, relay control, and leakage-current-related circuitry. J1 is a 3-pin locking connector used for connections to exciter relay auxiliary contacts. E1 and E2 are associated with the positive and negative field bus voltage connections, identified as Vbus-P and Vbus-N. TB1 provides the EXAM shield-ground connection to the cabinet frame ground. Because these interfaces perform different electrical functions, they must be identified carefully during installation and maintenance. In particular, E1 and E2 are associated with the excitation field voltage circuit and should only be handled after the system has been safely shut down and the relevant electrical conditions have been verified. Correct connector identification and wiring are essential for reliable ground detection and safe system operation.

7. What symptoms may indicate an IS200EXAMG1A fault?

A problem involving the IS200EXAMG1A may appear as abnormal ground detection alarms, failure to initiate a ground test, unstable ground-test results, incorrect relay operation, or failure to correctly identify the condition of the excitation field circuit. In a redundant EX2100 system, abnormal M1/M2 control-channel behavior may also be observed if the associated relay interface is affected. However, these symptoms do not automatically mean that the EXAM module itself has failed. Similar problems can originate from the EGDM module, EPBP backplane, field wiring, relay circuits, grounding connections, or the excitation field circuit itself. Troubleshooting should begin by reviewing the system alarm and event information and determining whether the problem occurs during a ground test or during normal operation. The J1, J2, E1, E2, and TB1 connections should then be inspected, followed by verification of the JP1, JP2, and JP3 configuration. If required, the EGDM and related control signals should also be tested before replacing the EXAM.

8. What precautions should be taken when replacing the IS200EXAMG1A?

Replacing the IS200EXAMG1A requires strict electrical safety procedures because the module interfaces with the excitation system field circuit and associated high-voltage circuitry. The EX2100 system should be placed in a safe maintenance state and fully de-energized before the module is handled. Technicians must verify that the relevant field and bus circuits have reached a safe voltage level using appropriate test equipment rather than relying only on the status of the main disconnect. Before removing the existing EXAM, all J1, J2, E1, E2, and TB1 connections should be clearly identified and documented. The positions of JP1, JP2, and JP3 should also be recorded so the replacement module can be configured correctly. After installation, all connectors and field wiring should be checked carefully before energizing the system. The ground detection function, relay operation, alarm signals, and associated control-channel behavior should then be tested. For TMR configurations, the redundant control paths should be verified individually to ensure that the replacement module has not introduced an imbalance or loss of ground detection functionality.

GE IS200EXAMG1A Exciter Attenuation Module is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996