GE UR 5EH Sensor I/O Module

  • Manufacturer: GE
  • Product Number: UR 5EH
  • Condition: New & In Stock
  • Product Type: Sensor I/O Module
  • Origin: USA
  • Payment Methods: T/T, Western Union
  • Dimensions: 120 x 30 x 100 mm
  • Weight: 1.15 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Model UR 5EH
Product Type Sensor I/O Module
Brand GE
Series Multilin Universal Relay
Module Type Transducer I/O Module
Primary Function Acquisition and processing of analog transducer and temperature signals
DC mA Inputs 4 channels
RTD Inputs 4 channels
Analog Input Type DC current transducer input
RTD Measurement Resistance Temperature Detector input
Signal Processing Converts field analog signals into data usable by the UR relay
Digital Inputs Not provided
Relay Outputs Not provided
Typical Application Transformer, generator, feeder and industrial protection systems
System Integration GE Multilin Universal Relay
Configuration Configured according to the associated UR relay application
Installation Horizontal plug-in module installation
Module Architecture Modular UR-series design
Signal Scaling Supports signal scaling within the associated relay configuration
Maintenance Module replacement, wiring inspection and signal verification
Operating Environment Industrial power protection and automation environment
Lifecycle Status Discontinued
Dimensions 120 × 30 × 100 mm
Weight 1.15 kg

FAQ

1. What is the main function of the GE UR 5EH Sensor I/O Module?
The GE UR 5EH is a transducer I/O module used with the GE Multilin Universal Relay series. Its primary function is to acquire analog transducer signals and RTD temperature signals and provide the corresponding measurement information to the associated UR relay. The module provides four DC mA input channels and four RTD input channels, making it suitable for applications where process measurements and temperature information need to be incorporated into a protection and monitoring system. Unlike digital I/O modules, the UR 5EH is focused on analog and temperature measurement and does not provide conventional digital input channels or relay output contacts. This makes it particularly useful when continuous process values need to be monitored by a Universal Relay.

2. How many input channels does the UR 5EH provide?
The UR 5EH provides four DC mA input channels and four RTD input channels. The four mA inputs can be used for compatible analog transducer signals, while the four RTD channels are intended for resistance temperature measurement. This combination allows one module to collect both process-related analog signals and temperature information within the same UR relay architecture. During commissioning, each channel should be assigned to the appropriate measurement type and configured with the correct scaling or sensor parameters. Incorrect configuration can result in inaccurate engineering values even when the physical wiring is correct. The input channels should therefore be checked against the actual field instruments before the relay is placed into normal service.

3. Does the UR 5EH provide digital inputs or relay outputs?
The UR 5EH is primarily an analog and temperature input module and does not provide conventional digital input channels or relay output contacts. Its four DC mA inputs are intended for analog transducer signals, while its four RTD inputs are designed for temperature measurement. Digital status acquisition and relay output functions should therefore be provided by other appropriate I/O modules within the Universal Relay system when required. This distinction is important when selecting replacement hardware because a module that looks physically similar may have a completely different I/O function. Before replacement, the original UR module type and the required signal configuration should always be verified against the system design.

4. What types of signals can be connected to the UR 5EH?
The UR 5EH is designed to receive standard DC mA transducer signals through four analog input channels and RTD signals through four temperature input channels. The mA inputs can be used to monitor process measurements supplied by compatible current-output transducers, while the RTD channels can be connected to suitable resistance temperature detectors. In a protection or monitoring application, these inputs may be used to acquire temperature or other continuously varying process measurements that are required by the control and protection logic. The actual engineering range and scaling should be configured according to the connected instrument. Correct sensor type, wiring arrangement and software configuration are essential for obtaining reliable measurements.

5. How is the UR 5EH configured within a GE Universal Relay?
The UR 5EH is installed as a modular I/O component within a compatible GE Multilin Universal Relay system. After installation, the relay configuration must identify the appropriate I/O module and assign the individual channels to their intended measurement functions. For mA inputs, the configured scaling should correspond to the output range of the connected transducer. For RTD inputs, the correct sensor type and associated measurement parameters should be selected. After configuration, the actual field signal should be compared with the value displayed by the relay to confirm that the signal is being interpreted correctly. Point-by-point verification is especially important when the measurements are used by alarms, protection logic or control functions.

6. What should be checked if a UR 5EH input shows an incorrect measurement?
Troubleshooting should begin by checking the field instrument and wiring before replacing the I/O module. For an mA input, the actual current delivered by the transducer should be measured and compared with the value reported by the relay. For an RTD channel, the sensor wiring, sensor type and resistance value should be checked against the expected measurement. The terminal connections should also be inspected for looseness, corrosion or damaged conductors. After the physical signal has been verified, the UR relay configuration and channel scaling should be reviewed. Incorrect scaling or sensor selection can produce an incorrect displayed value even when the UR 5EH hardware is operating normally. If the field signal and configuration are confirmed to be correct but the measurement remains abnormal, the corresponding input channel and module should then be investigated.

7. Can the UR 5EH be replaced as an individual module?
Yes, the UR platform uses a modular architecture, allowing compatible I/O modules such as the UR 5EH to be serviced or replaced individually when permitted by the equipment design and maintenance procedure. Before replacement, the technician should verify the complete module identification and confirm that the replacement has the same functional configuration. The relay should be placed in the appropriate maintenance condition, and the required electrical isolation and ESD precautions should be followed. After installation, the module configuration should be checked and each mA and RTD channel should be tested against its corresponding field instrument. A successful replacement should be confirmed through actual measurement verification rather than relying only on the absence of a module alarm.

8. What applications are suitable for the GE UR 5EH?
The UR 5EH is suitable for protection, monitoring and automation applications where a GE Multilin Universal Relay needs to acquire analog transducer and temperature signals. Typical applications include transformer protection and monitoring, generator protection, feeder protection and industrial power systems. RTD inputs can be used to monitor temperatures associated with electrical equipment, while the mA channels can acquire compatible analog measurements from field transducers. The collected values can then be used by the UR relay for measurement, alarming, monitoring and other configured functions. Because the UR 5EH is a specialized analog/temperature I/O module, it should be selected when the application specifically requires these signal types rather than digital input or relay output functions.

GE UR 5EH Sensor I/O Module is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996