Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | GE |
| Model | IS200TBAIH1BBB |
| Product Type | Analog Input Terminal Board |
| Series | GE Mark VI |
| Functional Acronym | TBAI |
| Main Function | Analog signal termination, distribution, and interface between field instruments and the Mark VI I/O system |
| Analog Inputs | 10 channels |
| Analog Outputs | 2 channels |
| Supported Transmitters | 2-wire, 3-wire, 4-wire, and externally powered transmitters |
| Input Signal Types | Current and voltage analog signals |
| Typical Voltage Inputs | ±5 VDC and ±10 VDC, depending on configuration |
| Analog Output | 0–20 mA; one output can be configured for higher-current operation depending on system configuration |
| Transmitter Supply | 24 VDC source available for connected transducers |
| System Configuration | Simplex or TMR (Triple Modular Redundant) |
| I/O Processor Connections | 3 × DC-37 pin connectors |
| TMR Connections | JR1, JS1, and JT1 |
| Terminal Blocks | 2 field I/O terminal blocks |
| Terminal Capacity | 24 terminals per terminal block |
| Wiring | Supports field wiring up to #12 AWG |
| Signal Protection | Noise suppression circuitry for surge and high-frequency noise reduction |
| Jumper Configuration | Jumpers are used to configure current/voltage inputs, input return configuration, and output current selection |
| Compatible I/O Hardware | GE Mark VI VAIC analog I/O boards and associated control-system electronics |
| Typical Applications | Gas turbines, steam turbines, generator control, and industrial process control |
| Mounting | Control cabinet / terminal board assembly |
| Dimensions | 330.2 × 20 × 101.6 mm |
| Weight | 1.1 kg |
FAQ
1. What is the main function of the GE IS200TBAIH1BBB Analog Input Terminal Board?
The IS200TBAIH1BBB is used as an analog signal termination and interface board in the GE Mark VI control system. It provides the field wiring interface for analog transmitters and routes the collected signals to the associated I/O processing electronics. Typical applications include pressure, temperature, flow, level, and other process measurements used by turbine control systems. The board is designed to handle the practical wiring and signal-distribution requirements between field instruments and the Mark VI control architecture.
2. How many analog input and output channels does the IS200TBAIH1BBB support?
The TBAI board provides 10 analog input channels and 2 analog output channels. The input channels can accommodate different transmitter wiring arrangements, including two-wire, three-wire, four-wire, and externally powered transmitters. The two output channels provide analog control signals to external devices. The exact signal configuration should be matched with the associated VAIC I/O board and the control-system application.
3. What types of transmitters can be connected to the IS200TBAIH1BBB?
The board is designed to support a wide range of industrial transmitters. Two-wire transmitters, three-wire transmitters, four-wire transmitters, and externally powered transmitters can be connected when the corresponding Mark VI configuration is used. Voltage and current input arrangements can also be selected through the board’s configuration jumpers. This allows the same terminal-board design to be used with different types of field instrumentation without requiring a completely different termination assembly.
4. Can the IS200TBAIH1BBB be used in a TMR control system?
Yes. The TBAI architecture supports both Simplex and TMR applications. In a TMR configuration, the analog input signals can be distributed to the R, S, and T control channels through the JR1, JS1, and JT1 connections. This arrangement allows the redundant control channels to receive corresponding field measurements and supports the fault-tolerant architecture used by critical turbine control systems. Correct configuration of the associated I/O processors and wiring is essential when installing the board in a TMR system.
5. What are the three DC-37 connectors on the IS200TBAIH1BBB used for?
The three DC-37 connectors provide the interface between the TBAI terminal board and the Mark VI I/O processing electronics. They are identified as JR1, JS1, and JT1 and are particularly important in TMR installations, where separate control channels need access to the corresponding analog signals. In a Simplex installation, the appropriate connector is used according to the system configuration. The connectors should be inspected carefully during maintenance because poor contact, damaged pins, or incorrect cable installation can result in multiple channel communication or signal problems.
6. How should an abnormal analog input signal on the IS200TBAIH1BBB be diagnosed?
Troubleshooting should begin at the field instrument rather than immediately replacing the terminal board. First verify the transmitter power supply and confirm that the transmitter is producing the expected current or voltage. Then check the polarity, terminal connections, shield connections, and field wiring. If the field signal is correct, inspect the DC-37 connection between the TBAI board and the I/O processor. The associated VAIC board and system configuration should also be checked. Comparing the affected channel with a known-good channel can help determine whether the problem originates from the transmitter, wiring, terminal board, I/O electronics, or software configuration.
7. Does the IS200TBAIH1BBB provide protection against electrical noise?
Yes. The TBAI design incorporates signal-conditioning and noise-suppression circuitry intended to reduce the effects of surge and high-frequency electrical noise on analog signals. This is important in turbine and industrial control cabinets where motors, generators, drives, contactors, and other high-power equipment can introduce electrical interference. Proper field wiring remains important, however. Shielding, grounding, cable routing, and separation from high-voltage conductors should follow the installation requirements of the overall Mark VI control system.
8. What should be checked when replacing an IS200TBAIH1BBB in an existing Mark VI system?
Before replacement, verify the complete board part number and revision and record the existing jumper configuration and field wiring. The replacement board should be installed with the same signal configuration unless the system engineering documentation specifies a change. Check the two terminal blocks, field wiring, shields, and the JR1/JS1/JT1 connectors for loose or damaged connections. After installation, verify transmitter power, analog input readings, output operation, and system diagnostic status. In a TMR application, all three control paths should be checked to ensure that the redundant channels are receiving consistent signals and that no new diagnostic or hardware mismatch alarms have appeared.
GE IS200TBAIH1BBB Analog Input Terminal Board is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.