Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | ABB |
| Product Series | ACS580 |
| Product Type | Variable Frequency Drive |
| Model | ACS580-01-026A-4 |
| Ordering Number | 3AXD50000038960 |
| Input Voltage | 380–480 V AC |
| Input Voltage Range | 380–480 V AC, ±10% |
| Input Phase | Three-phase |
| Input Frequency | 50/60 Hz |
| Rated Output Current | 26 A |
| Output Frequency | 0–500 Hz |
| Typical Motor Power | 15 kW |
| Motor Control Method | Scalar control (U/f), vector control |
| Compatible Motors | Three-phase induction motors and permanent magnet motors where applicable |
| Installation Method | Wall-mounted |
| Cooling Method | Forced-air cooling |
| Protection Rating | IP21 |
| Control Interfaces | Digital inputs/outputs, analog inputs/outputs |
| Communication | Fieldbus communication available through optional communication modules |
| Operating Temperature | -15 to +50 °C; derating may be required above the specified ambient temperature |
| Relative Humidity | 5–95%, non-condensing |
| Dimensions | 473 × 125 × 229 mm |
| Weight | 6.6 kg |
| Typical Applications | Conveyors, pumps, fans, compressors, industrial machinery and general-purpose drive systems |
| Main Functions | Motor speed control, torque control, start/stop control, operating monitoring and motor protection |
FAQ
1. What are the main industrial applications of the ABB ACS580-01-026A-4?
The ABB ACS580-01-026A-4 is a variable frequency drive designed for industrial motor speed control applications. It is suitable for equipment that requires continuous motor speed adjustment, controlled starting, or process-based motor control. Typical applications include conveyors, fans, pumps, compressors and general industrial machinery. For pumps and fans, variable-speed control can adjust motor operation according to actual process requirements, while conveyors can benefit from controlled acceleration, deceleration and speed references. During selection, the motor rated current, load type, operating cycle and overload requirements should be considered rather than selecting the drive based only on nominal motor power.
2. What is the rated output current of the ACS580-01-026A-4?
The rated output current of the ACS580-01-026A-4 is 26 A. This is an important parameter when matching the drive with a motor. The selection process should not be based only on comparing the drive power rating with the motor power rating. The motor nameplate rated current should also be checked, together with the actual mechanical load and its starting torque or continuous overload requirements. For heavy-duty applications, frequent starting and stopping, or rapid acceleration and deceleration, the applicable current and overload capability should be evaluated carefully. Correct current matching helps reduce the risk of overcurrent, overheating and unexpected protective trips.
3. Which motor parameters should be configured during initial ACS580-01-026A-4 commissioning?
During initial commissioning, the basic motor parameters should be entered according to the actual motor nameplate. These normally include motor rated voltage, rated current, rated frequency, rated speed and rated power. These values directly affect the drive control algorithm, output current behavior and motor protection functions, so the settings should accurately correspond to the connected motor. After entering the motor data, the start command, stop command, frequency reference and forward/reverse control logic should also be checked. For applications requiring stable speed or improved torque response, the appropriate motor control mode and identification or optimization procedures should be configured according to the application.
4. How should an overcurrent fault on the ACS580-01-026A-4 be diagnosed?
When an overcurrent fault occurs, first check whether the driven machine has mechanical blockage, excessive friction, abnormal bearings or a sudden increase in load. The motor power cables and terminals should then be inspected for phase-to-phase short circuits, ground faults or incorrect wiring. If the mechanical and electrical circuits appear normal, check whether the acceleration time is too short, as rapid acceleration can require a significant amount of motor current. The motor rated current, rated voltage, rated frequency and selected control mode should also be verified. If the overcurrent fault occurs only during startup, acceleration or a particular load condition, monitoring output frequency, motor current and load changes at the time of the fault can help identify the actual cause.
5. What should be checked if the motor does not start after the ABB ACS580-01-026A-4 is powered on?
If the motor does not start, first check whether the drive has an active fault, alarm or start inhibit condition. Next, verify the source of the start command. If the drive is controlled from the keypad, confirm that the run command is correctly issued. If external terminal control is used, inspect the digital input signals, start/stop wiring and control voltage. For PLC or automation-system control, verify the communication status, run command and frequency reference. The frequency reference should also be checked to ensure that it is not set to zero. External interlocks, emergency-stop circuits, safety circuits and other permissive conditions should be inspected because any of these can prevent the drive from producing an output even when the main power supply is normal.
6. What commonly causes an overtemperature alarm on the ABB ACS580-01-026A-4?
Overtemperature conditions are commonly caused by excessive ambient temperature, inadequate cabinet ventilation, blocked cooling passages, cooling fan problems or prolonged operation at high load. The drive should be installed in a location with adequate airflow and should not be positioned close to significant heat sources or inside an enclosure with insufficient heat dissipation. If the drive operates continuously near its rated output current, the actual ambient temperature should be checked against the applicable derating requirements. During maintenance, the cooling fan, heat sink and ventilation passages should be inspected and cleaned when necessary. If overtemperature alarms continue under normal load and reasonable ambient conditions, the cooling system and temperature monitoring functions should be investigated further.
7. How should the acceleration and deceleration times be configured for the ACS580-01-026A-4?
Acceleration and deceleration times should be selected according to motor power, mechanical load inertia, process requirements and the amount of mechanical shock that the equipment can tolerate. For high-inertia loads, an acceleration time that is too short can demand excessive motor current and potentially trigger an overcurrent protection function. During deceleration, an excessively short time can cause regenerative energy to increase the DC bus voltage and potentially result in an overvoltage fault. During commissioning, it is generally better to begin with relatively conservative acceleration and deceleration times and then optimize them according to motor current, machine response and actual fault behavior. Applications involving frequent deceleration, high inertia or rapid stopping should also be evaluated for braking resistor requirements.
8. How can the ABB ACS580-01-026A-4 be integrated with a PLC or DCS system?
The ACS580-01-026A-4 can be controlled through local controls, digital signals and analog signals for basic start/stop and speed control. It can also be integrated with PLC, DCS and other automation systems through an appropriate communication module when fieldbus control is required. In an automation application, the PLC or DCS can send commands such as start, stop, forward/reverse and speed reference, while receiving operating status, actual frequency, current and fault information from the drive. When communication is used, the applicable communication module and protocol must be configured correctly, including network address, communication parameters, control words, status words and speed-reference scaling. Before commissioning, the complete control sequence should be tested, including start/stop commands, fault feedback, communication-loss behavior and external safety interlocks.
ABB ACS580-01-026A-4 3AXD50000038960 Variable Frequency Drive is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.