  • Manufacturer: ABB
  • Product Number: CM‑MPS.21 1SVR630885R3300
  • Condition: New & In Stock
  • Product Type: Three-Phase Monitoring Relay
  • Origin: Sweden (SE)
  • Payment Methods: T/T, Western Union
  • Dimensions: 100 x 22.5 x 78 mm
  • Weight: 0.135 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Model CM-MPS.21
Order Number 1SVR630885R3300
Product Type Three-Phase Monitoring Relay
Manufacturer ABB
Product Series CM-MPS
Monitoring Type Multifunctional Three-Phase Monitoring Relay
Main Functions Phase sequence, phase failure, overvoltage, undervoltage, phase unbalance and interrupted neutral monitoring
Measuring Principle True RMS (TRMS)
Measuring Voltage 3 × 180–280 V AC
Rated Control Supply 3 × 180–280 V AC
Monitoring Network Three-phase AC mains
Single-Phase Monitoring Supported
Phase Sequence Monitoring Selectable ON/OFF
Phase Failure Detection Supported
Overvoltage Monitoring Supported
Undervoltage Monitoring Supported
Phase Unbalance Monitoring Adjustable threshold
Interrupted Neutral Monitoring Supported
Overvoltage Threshold Adjustable
Undervoltage Threshold Adjustable
Phase Unbalance Threshold Adjustable up to 25%
Tripping Delay 0 s or 0.1–30 s
Tripping Delay Mode ON-delay or OFF-delay selectable
Start-Up Delay Approximately 200 ms
Output Contacts 2 c/o (SPDT)
Contact Configuration Changeover contacts
Contact Rating Up to 4 A AC-12 at 230 V AC
Terminal Type Screw terminals
Mounting DIN rail mounting
Status Indicators 3 LEDs
Adjustment Front-panel adjustment controls
Housing Material UL 94 V-0 rated material
Operating Temperature -25 to +60 °C
Storage Temperature -40 to +85 °C
Standards IEC/EN 60255-1, EN 50178
Typical Applications Motor protection, power supply monitoring, phase monitoring and industrial automation
Typical Installation Industrial control cabinets and electrical distribution systems
Dimensions 100 × 22.5 × 78 mm
Weight 0.135 kg

FAQ

1. What is the main function of the ABB CM-MPS.21 monitoring relay?

The ABB CM-MPS.21 is a multifunctional three-phase monitoring relay designed to continuously supervise important electrical parameters in three-phase AC systems. It can detect phase sequence errors, phase failure, overvoltage, undervoltage, phase unbalance and interrupted neutral conditions. The relay uses a True RMS measuring principle to evaluate the monitored voltage and provides relay outputs that can be connected to contactors, alarms, controllers or other protection circuits. Because several monitoring functions are integrated into one device, the CM-MPS.21 can be used as a compact protection and monitoring solution in industrial control cabinets and electrical distribution systems. The monitored thresholds can be adjusted from the front panel, allowing the relay to be adapted to different operating conditions. When an abnormal voltage or phase condition is detected, the output contacts change state after the configured delay, allowing the associated equipment to be disconnected or an alarm to be generated.

2. What voltage range does the CM-MPS.21 monitor?

The CM-MPS.21 is designed for monitoring a three-phase AC system in the 180–280 V AC range. The measuring voltage is also used as the control supply, so the relay is powered directly from the monitored circuit rather than requiring a separate auxiliary power supply. This arrangement simplifies installation in many industrial applications. The relay continuously evaluates the monitored voltage and compares it with the configured overvoltage and undervoltage thresholds. When the voltage moves outside the permitted range for longer than the configured delay, the output relay changes state. Before installation, the actual system voltage should be checked to ensure that it falls within the specified measuring range. Incorrect voltage selection can result in improper operation or damage to the monitoring relay. The phase connections should also be made according to the recommended wiring arrangement to ensure that phase sequence, phase failure and unbalance monitoring operate correctly.

3. Which electrical faults can the CM-MPS.21 detect?

The CM-MPS.21 can detect several common three-phase power-system abnormalities. Its monitoring functions include phase sequence, phase failure, overvoltage, undervoltage, phase unbalance and interrupted neutral detection. Phase sequence monitoring can identify incorrect phase rotation, which is particularly useful for applications involving three-phase motors where incorrect rotation could cause undesirable mechanical operation. Phase failure detection identifies the loss of one phase, while overvoltage and undervoltage monitoring protect connected equipment from sustained abnormal voltage conditions. The phase unbalance function monitors differences between the three phase voltages and can be configured according to the required protection level. The CM-MPS.21 also includes interrupted neutral monitoring, which is an important feature for detecting neutral conductor problems in suitable systems. These functions allow one monitoring relay to supervise several electrical conditions simultaneously instead of requiring separate relays for every individual fault.

4. Can the CM-MPS.21 be used to monitor a single-phase power supply?

Yes. The CM-MPS.21 can also be used for single-phase monitoring when configured correctly. For single-phase operation, the three external conductor inputs are connected together and used as a common monitored conductor. Phase sequence monitoring must be disabled because there is no three-phase rotation to evaluate in a single-phase system. The phase unbalance threshold also needs to be configured appropriately, with the recommended maximum setting used for this operating mode. Correct wiring and configuration are essential because the relay is primarily designed as a multifunctional three-phase monitoring device. The single-phase application should therefore be implemented according to the appropriate connection diagram and configuration requirements. When converting the device from a three-phase application to a single-phase application, technicians should verify the wiring and function-selection settings before energizing the circuit. Incorrect configuration can result in false fault indications or prevent the intended monitoring function from operating correctly.

5. How does the adjustable tripping delay work on the CM-MPS.21?

The CM-MPS.21 provides an adjustable tripping delay that allows temporary electrical disturbances to be distinguished from sustained faults. The delay can be set to 0 seconds or adjusted from approximately 0.1 to 30 seconds using the front-panel adjustment. Depending on the selected function, the relay can operate with an ON-delay or OFF-delay response. This is useful in industrial applications because voltage fluctuations can occur during motor starting, switching operations or other transient conditions. Without an appropriate delay, a short-duration voltage disturbance could cause unnecessary relay operation and potentially interrupt the controlled equipment. Conversely, setting the delay too long could allow a genuine electrical fault to remain present for an undesirable period. The correct delay should therefore be selected according to the characteristics of the monitored electrical system and the response requirements of the connected equipment. During commissioning, the actual system behavior should be observed to ensure that the selected delay provides adequate protection without causing unnecessary trips.

6. What do the three LEDs on the CM-MPS.21 indicate?

The CM-MPS.21 uses three front-panel LEDs to provide a convenient indication of the relay’s operating and fault status. The indicators allow technicians to determine whether the device is operating normally and whether a monitored electrical abnormality has been detected. The relay-status indicator provides information about the operating or timing condition, while the fault indicators are associated with detected monitoring faults. These visual indicators are particularly useful during commissioning because they provide immediate information without requiring additional diagnostic equipment. However, the LEDs should not be considered a replacement for electrical measurements when troubleshooting. If a fault LED is illuminated, the technician should identify which monitoring condition has been triggered and then measure the relevant phase voltages to determine whether the fault is actually present in the electrical system. Checking the LED state together with measured phase voltage, phase sequence and relay output status provides a more reliable method of determining whether the problem is caused by the monitored power system or by the monitoring relay itself.

7. Why might the CM-MPS.21 repeatedly trip even when the power system appears normal?

Repeated unwanted tripping can have several causes. The most common possibilities include incorrectly adjusted overvoltage or undervoltage thresholds, excessive phase unbalance, an inappropriate tripping delay, incorrect phase wiring or short-duration voltage disturbances that are not obvious during a basic voltage check. Loose terminals or damaged wiring can also cause intermittent voltage loss on one phase, resulting in repeated phase-failure detection. If the system is operating close to the configured voltage threshold, normal variations may be interpreted as an abnormal condition. The first troubleshooting step should be to measure all three phase voltages under normal operating conditions and compare them with the relay settings. The phase sequence should also be verified if phase-sequence monitoring is enabled. Next, inspect the wiring and terminals for loose connections or signs of overheating. If the electrical system is confirmed to be stable, the relay’s threshold and timing settings should be reviewed. An appropriately selected delay can prevent brief transients from causing unnecessary relay operation.

8. What should be checked when replacing an ABB CM-MPS.21?

Before replacing a CM-MPS.21, the technician should first determine whether the relay itself has failed or whether an external electrical fault is causing the abnormal indication. The three-phase supply, phase sequence, phase voltages, neutral connection and wiring should be checked first. The existing threshold settings and tripping-delay settings should also be recorded before removing the original device so that the replacement can be configured consistently. The correct model and order number should be verified, particularly when working with older installations. For this product, the specified model is CM-MPS.21 and the order number is 1SVR630885R3300. During installation, the phase conductors and neutral connection should be connected to the appropriate terminals, and the relay should be securely mounted on the DIN rail. After installation, the operating voltage, phase sequence, monitoring thresholds and relay output behavior should be tested. Where possible, controlled fault simulations should be used to confirm phase-failure, voltage-limit and unbalance detection. The connected contactor, alarm circuit or controller should also be checked to ensure that the relay output is correctly interpreted by the rest of the control system.

ABB CM‑MPS.21 1SVR630885R3300 Three-Phase Monitoring Relay is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996