Technical Specifications
| Item | Description |
|---|---|
| Brand | Schneider Electric |
| Model | NW10H2 |
| Product Series | MasterPact NW |
| Product Type | Low Voltage Air Circuit Breaker (ACB) |
| Rated Current | 1000 A at 40°C |
| Rated Operational Voltage | 690 V AC, 50/60 Hz |
| Rated Insulation Voltage | 1000 V AC |
| Rated Impulse Withstand Voltage | 12 kV |
| Number of Poles | 4P |
| Neutral Position | Left Neutral |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 100 kA at 440 V AC; 85 kA at 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 100 kA at 440 V AC; 85 kA at 690 V AC |
| Rated Short-Time Withstand Current (Icw) | 85 kA for 1 second; 50 kA for 3 seconds |
| Rated Short-Circuit Making Capacity (Icm) | 187 kA at 440 V AC |
| Breaking Capacity Class | H2 |
| Utilization Category | Category B |
| Mounting Type | Fixed |
| Control Unit | Without Control Unit |
| Operating Method | Push-button |
| Suitability for Isolation | Yes, according to EN/IEC 60947-2 |
| Power Dissipation | 70 W |
| Maximum Breaking Time | 25 ms |
| Maximum Closing Response Time | 70 ms |
| Mechanical Durability | 12,500 operations (maintenance-free); 25,000 operations (with maintenance) |
| Applicable Standards | EN/IEC 60947-1, EN/IEC 60947-2 |
| Dimensions | 352 × 537 × 297 mm |
| Weight | 65 kg |
FAQ
1. What is the main function of the Schneider NW10H2 air circuit breaker?
The Schneider Electric NW10H2 belongs to the MasterPact NW series of low-voltage air circuit breakers. It is designed to protect industrial power distribution systems and large electrical installations. When an overload or short circuit occurs, the breaker interrupts the current to help protect cables, busbars, switchgear, and downstream loads. With a rated current of 1000 A and an H2 breaking-capacity class, it is intended for applications that require high short-circuit interruption performance and reliable power distribution protection. It is an air circuit breaker, not a conventional contactor.
2. What are the advantages of the H2 breaking-capacity class on the NW10H2?
The H2 designation identifies a high short-circuit breaking-capacity level. The NW10H2 has a rated ultimate short-circuit breaking capacity (Icu) of 100 kA at 440 V AC and 85 kA at 690 V AC. Its rated service short-circuit breaking capacity (Ics) is also 100 kA and 85 kA at these respective voltage levels. These ratings describe the breaker’s ability to interrupt fault currents under specified test conditions. They are not normal operating current values. Before installation, engineers should compare the ratings with the prospective short-circuit current at the installation point.
3. What are the rated current and operating voltage of the NW10H2?
The NW10H2 has a rated current of 1000 A at 40°C and a rated operational voltage of up to 690 V AC at 50/60 Hz. Its rated insulation voltage is 1000 V AC, while its rated impulse withstand voltage is 12 kV. Actual application suitability depends on the load characteristics, supply voltage, ambient temperature, and prospective short-circuit current. If the operating load remains close to the rated current for extended periods, the busbars, terminals, and ventilation conditions should also be checked to ensure reliable operation.
4. What is the purpose of the NW10H2 rated short-time withstand current (Icw)?
The rated short-time withstand current indicates the fault-current level the breaker can withstand for a specified period without unacceptable damage. The NW10H2 has an Icw rating of 85 kA for 1 second and 50 kA for 3 seconds. This characteristic is important in protection selectivity and coordination between upstream and downstream circuit breakers. In a properly designed distribution system, an upstream breaker may be configured with a time delay so that a downstream protective device can clear a fault first. The actual coordination settings must be verified against the system’s fault-current levels and protection design.
5. How should frequent tripping of the NW10H2 be diagnosed?
Frequent tripping may be caused by excessive load current, downstream short circuits, damaged cable insulation, loose connections, or an unsuitable protection arrangement. Start by reviewing system alarms and available fault records to identify the operating conditions when tripping occurs. Then inspect the main circuit connections, cables, and downstream equipment for overheating, insulation faults, or short circuits. Since this version is supplied without a control unit, the overall protection arrangement should also be checked. Avoid repeatedly resetting the breaker before the underlying fault has been identified.
6. What should be considered when installing the NW10H2 without a control unit?
The “without control unit” configuration means that the specified electronic trip or protection unit is not included. Before installation, determine whether a separate protection device is required and how overload and short-circuit protection will be implemented in the overall system. Confirm that any associated protection components are compatible with the breaker and the switchboard design. After installation, inspect the main circuit connections and control circuits, then complete the required protection and functional tests. The breaker’s electrical ratings alone do not establish that the complete protection system is suitable.
7. How should the Schneider NW10H2 be maintained?
Maintenance should follow Schneider Electric’s technical documentation and the site’s electrical maintenance procedures. Regular inspections should cover the main circuit terminals, contacts, insulation components, and mechanical operating mechanism. Look for abnormal heating, poor electrical contact, corrosion, contact damage, or mechanical wear. The opening and closing mechanisms should also be checked for reliable operation. Inspection frequency should reflect operating conditions, switching frequency, and the electrical environment. All maintenance work must be performed by qualified electrical personnel after the equipment has been safely de-energized and isolated.
8. Can the NW10H2 replace another MasterPact NW circuit breaker?
Not automatically. Before replacement, compare the rated current, breaking-capacity class, number of poles, neutral position, fixed or drawout configuration, control-unit arrangement, and main circuit connections. For example, the NW10H1 and NW10H2 are both part of the 1000 A MasterPact NW range, but their short-circuit breaking capacities differ. The replacement must also be compatible with the existing switchboard, busbar arrangement, and protection system. Always verify the complete product reference and configuration before ordering or installing a replacement breaker.
Schneider NW10N2 Contactor is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666084105 | |||||||
| +8613666084105 | ||||||||
| 13666084105 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.