Your Trusted PLC & DCS Supplier!
100% Original, Ready to Ship!

Schneider VW3A7101 Resistance Braking Unit

  • Manufacturer: Schneider
  • Product Number: VW3A7101
  • Condition: New & In Stock
  • Product Type: Resistance Braking Unit
  • Origin: France
  • Payment Methods: T/T, Western Union
  • Dimensions: 3700 x 1100 x 490 mm
  • Weight: 30 kg
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.

Product Detail

Contact Us

FAQS

Packing & Delivery

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 15305023276
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Technical Specifications

Parameter Specification
Model VW3A7101
Product Type Braking Unit
Rated Voltage 400 V
Maximum Braking Power 420 kW
Continuous Braking Power 200 kW at 400 V
Minimum Braking Resistor Value 1.05 Ω
Braking Activation Threshold 785 V DC ±1%
Maximum DC Bus Voltage 850 V DC
Thermal Loss 550 W
Thermal Protection Integrated thermal protection with thermal probe
Cooling Air Flow 100 m³/h
Installation Position Vertical installation
Protection Rating IP20
Operating Temperature -10 to +50 °C
Storage Temperature -25 to +70 °C
Maximum Operating Altitude 2000 m
Pollution Degree Pollution degree 2, according to EN 50178
Duty Cycle 420 kW at 5%; 320 kW at 15%; 250 kW at 50%
Electrical Connection Cable connection between the drive and braking unit
Braking Resistor Connection 2 × 95 mm²
Compatible Drive Series Altivar 61, Altivar 61Q, Altivar 71, Altivar 71Q, Altivar Process ATV900
Dimensions 3700 × 1100 × 490 mm
Weight 30 kg

FAQ

1. What is the main function of VW3A7101 in a variable speed drive system?
VW3A7101 is designed to manage regenerative energy generated by a motor during deceleration, rapid stopping, or other braking conditions. When a motor changes from motoring operation to regenerative operation, the electrical energy returned from the motor causes the DC bus voltage of the drive to increase. If this energy cannot be absorbed by the normal drive system, the DC bus voltage may rise beyond its permissible level and cause a DC overvoltage fault. VW3A7101 provides a controlled path for this excess energy to be transferred to an external braking resistor, where the electrical energy is converted into heat. This allows the drive to achieve faster and more controlled deceleration and is particularly useful for high-inertia machinery, frequent stopping applications, lifting equipment, conveyors, centrifuges, and other industrial systems requiring dynamic braking.

2. What is the maximum braking power of VW3A7101?
The maximum braking power of VW3A7101 is 420 kW under the specified operating conditions. However, 420 kW should not be considered as a continuous braking rating. The allowable braking power depends on the duty cycle and the amount of time that regenerative energy must be dissipated. For example, the unit can support approximately 420 kW at a 5% duty cycle, 320 kW at a 15% duty cycle, and 250 kW at a 50% duty cycle. When selecting the braking unit and resistor for an actual installation, engineers should evaluate motor power, load inertia, deceleration time, stopping frequency, and the expected regenerative energy. Correctly matching these factors is important because excessive or continuous braking can produce significant thermal stress on the braking system.

3. What braking resistor should be used with VW3A7101?
The minimum permitted braking resistor value for VW3A7101 is 1.05 Ω. The selected resistor should not have a resistance value below this limit because a resistance that is too low can result in excessive braking current and place excessive electrical stress on the braking unit and DC bus circuit. In addition to resistance value, the resistor must have sufficient power and thermal capacity for the actual braking duty cycle. A resistor that satisfies the resistance requirement but has insufficient thermal capacity may overheat during repeated braking operations. For demanding applications, the resistor selection should therefore be based on both instantaneous braking power and average energy dissipation over the complete operating cycle.

4. At what DC voltage does VW3A7101 activate its braking function?
VW3A7101 has a braking activation threshold of approximately 785 V DC ±1%. During regenerative operation, the motor returns energy to the drive’s DC bus, causing the DC bus voltage to increase. When the voltage reaches the specified braking threshold, the braking unit operates to direct the excess energy toward the braking resistor. This prevents the DC bus voltage from continuing to rise during deceleration. The maximum DC bus voltage is specified as 850 V DC, so correct operation of the braking unit is important for maintaining the voltage within an acceptable range. Incorrect wiring, an unsuitable braking resistor, or insufficient braking capacity can prevent the system from handling regenerative energy properly and may result in DC overvoltage faults.

5. How does the thermal protection of VW3A7101 work?
VW3A7101 incorporates thermal protection using a thermal probe to monitor temperature conditions. During braking, regenerative electrical energy is converted into heat through the braking resistor, and this process can generate substantial thermal loading. The braking unit and resistor therefore require suitable ventilation and sufficient heat dissipation. The thermal protection system helps prevent operation from continuing under excessively high temperature conditions. However, thermal protection should not be considered a replacement for proper system design. Engineers should also evaluate ambient temperature, enclosure ventilation, installation conditions, braking frequency, average braking power, and resistor thermal capacity. If the system repeatedly approaches its thermal limits, the braking duty cycle or cooling arrangement should be reviewed.

6. Which Schneider Electric drive series can be used with VW3A7101?
VW3A7101 is intended for use with selected high-power Schneider Electric Altivar drive systems, including Altivar 61, Altivar 61Q, Altivar 71, Altivar 71Q, and applicable Altivar Process ATV900 configurations. Compatibility should always be checked against the specific drive model, voltage class, power rating, and application requirements before installation. The braking unit is not selected solely according to motor power. The drive’s DC bus characteristics, regenerative energy, required deceleration performance, braking resistor specifications, and operating duty must also be considered. For a new installation, the complete drive, braking unit, braking resistor, motor, and load should be evaluated as one braking system rather than treating the braking unit as an independent component.

7. What should be considered when connecting VW3A7101 to the braking resistor?
The connection between VW3A7101 and the braking resistor is a critical part of the braking system because high current can flow through this circuit during regenerative braking. The specified braking resistor connection uses 2 × 95 mm² conductors, and the actual installation should follow the applicable electrical and installation requirements. The cables must have adequate current-carrying capacity, insulation performance, and temperature resistance for the expected braking conditions. Connections should also be properly tightened to minimize contact resistance and localized heating. Cable routing should be planned to reduce unnecessary heat accumulation and to maintain appropriate separation from sensitive control or signal wiring. Before commissioning, the complete braking circuit should be inspected for correct connections, appropriate resistor value, secure terminals, and signs of insulation damage or overheating.

8. How can a VW3A7101 braking fault be diagnosed systematically?
When VW3A7101 does not provide the expected braking performance, troubleshooting should begin with the DC bus voltage and the operating condition of the drive. First, determine whether the DC bus voltage actually rises during deceleration and whether it reaches the braking activation threshold. Next, verify the drive configuration and braking-related parameters to ensure that the braking function is correctly enabled and configured for the application. The wiring between the drive, VW3A7101, and braking resistor should then be inspected carefully, including terminal connections, cable condition, conductor sizing, and circuit continuity. The resistance of the external braking resistor should also be measured after ensuring that the system is safely isolated, and the measured value should be checked against the specified minimum resistance. If the electrical circuit is correct, inspect the thermal protection status and look for evidence of resistor overheating or insufficient ventilation. For repeated DC overvoltage faults, the braking capacity should be compared with the actual load inertia, deceleration time, stopping frequency, and duty cycle. This systematic approach helps distinguish electrical connection problems from incorrect parameter settings, insufficient braking capacity, or thermal limitations.

Schneider VW3A7101 Resistance Braking Unit is in stock. Please contact us for a quick quote and competitive pricing.

Company Information
e-mail [email protected]
Mobile +8615305023276
Whatsapp +8615305023276
WeChat 13950166376
Add to Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China


Company Introduction

Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.

We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.

Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.

Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia

Our Mission

Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.

Does this product come with a warranty?

We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.

How to Verify Products Before Purchase?

We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.

How long does shipping take?

Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.

What is the minimum order quantity (MOQ)?

The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.

Can I get discounts for bulk purchases of products?

Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.

What payment methods do you accept for wholesale orders?

We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.

Can I purchase different quantities of a product?

Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.

Are there any discounts or promotions available for new wholesale customers?

We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.

When purchasing a product, how can I ensure compatibility with my existing systems?

If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.

Can I return the goods I received if they do not meet our requirements?

Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.

Do you provide technical support or installation services to wholesale customers?

Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.

Hot Tags :

 

Prev or Next:

Send Us An Inquiry


Write your inquiry here and send it to us

Send Us An Inquiry


No:86996