Schneider ATS48C59Q Soft Starter
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 15305023276 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Model | ATS48C59Q |
| Product Series | Altistart 48 |
| Product Type | Soft Starter |
| Application | Three-Phase Asynchronous Motors |
| Application Area | Heavy-Duty Industry and Pump Applications |
| Utilization Category | AC-53A |
| Rated Current | 560 A |
| Operating Voltage | 230–415 V AC |
| Supply Frequency | 50–60 Hz |
| Motor Power at 230 V | 132 kW–250 kW, depending on connection and duty |
| Motor Power at 400 V | 250 kW–400 kW, depending on connection and duty |
| Motor Connection | In-Line or Inside-Delta Connection |
| Starting Method | Soft Starting with Torque Control |
| Stopping Function | Soft Stopping / Controlled Deceleration |
| Motor Protection | Integrated Motor Thermal Protection |
| Starter Protection | Integrated Starter Thermal Protection |
| Phase Protection | Line Phase-Failure Detection |
| Discrete Inputs | 5 |
| Discrete Input Type | PTC and Logic Inputs |
| Discrete Outputs | 2 Logic Outputs |
| Relay Outputs | Fault, End of Starting, Motor Powered |
| Analog Output | 0–20 mA or 4–20 mA |
| Analog Output Load | <500 Ω |
| Communication Protocol | Modbus |
| Communication Interface | RS485 Multidrop |
| Communication Connector | RJ45 |
| Communication Speed | 4800, 9600 or 19200 bps |
| Standards | EN/IEC 60947-4-2 |
| Certifications | UL, CSA, CCC, DNV and others depending on configuration |
| Mounting Position | Vertical ±10° |
| External Bypass | Optional |
| Dimensions | 670 × 400 × 300 mm |
| Weight | 51.4 kg |
FAQ
1. What is the main function of the Schneider ATS48C59Q soft starter?
The Schneider Electric ATS48C59Q is an Altistart 48 soft starter designed to control the starting and stopping of three-phase asynchronous motors. Instead of applying full motor voltage immediately, the soft starter controls the motor’s electrical supply during acceleration, helping reduce starting current and mechanical stress.
The ATS48C59Q uses torque-controlled soft-start technology and is intended for demanding industrial applications, including heavy-duty machinery and pump systems. It is rated for high-current motor applications and can operate with motors connected either directly in the motor supply line or using an inside-delta configuration.
During starting, the soft starter gradually increases the effective voltage applied to the motor so that acceleration is smoother than with direct-on-line starting. It can also provide controlled stopping, motor thermal protection, starter thermal protection, and phase-failure monitoring. These functions make the ATS48C59Q suitable for applications where reducing mechanical shock and controlling motor acceleration are important.
2. What motor power range is supported by the ATS48C59Q?
The ATS48C59Q is designed for high-power three-phase asynchronous motors, with the applicable motor power depending on the supply voltage, connection method, and duty classification.
At 230 V, the device can be used with motors from 132 kW to 250 kW depending on whether the motor is connected in the motor supply line or through the motor delta terminals and whether the application is classified as standard or severe duty. At 400 V, the applicable motor power can range from 250 kW to 400 kW under the corresponding connection and duty conditions.
This means that motor selection should not be based only on the maximum 400 kW figure. The actual application must be evaluated according to motor current, operating duty, starting conditions, supply voltage, connection method, and thermal requirements. Correct sizing is particularly important for heavy-duty applications where repeated starts or long acceleration times can increase thermal stress on the soft starter.
3. What supply voltage and frequency does the ATS48C59Q support?
The ATS48C59Q is designed for a three-phase AC operating voltage of 230–415 V with a supply frequency of 50–60 Hz. The applicable supply voltage must remain within the permitted range for the specific installation.
The selected motor and soft starter configuration must also be compatible with the actual power system. When commissioning the equipment, technicians should verify the incoming line voltage, motor nameplate information, phase sequence, and motor connection before enabling the starter.
The ATS48C59Q supports both in-line and inside-delta motor connection arrangements. These two connection methods have different current relationships and motor power capabilities, so the correct configuration must be selected during installation and parameter setup.
4. How does the ATS48C59Q reduce motor starting stress?
The ATS48C59Q controls the motor’s acceleration instead of allowing the motor to receive the full electrical supply immediately. This controlled starting process reduces the sudden current and torque changes associated with direct-on-line starting.
For mechanical systems such as pumps, compressors, conveyors, and heavy industrial machinery, reducing the initial torque shock can help minimize stress on couplings, gearboxes, shafts, belts, and other mechanical components. It can also reduce disturbances to the electrical supply caused by high motor starting current.
The ATS48 series uses torque-control functions to achieve controlled acceleration rather than relying only on a simple voltage ramp. The actual starting parameters should be adjusted according to the motor characteristics and load requirements. An excessively long acceleration time can increase thermal loading, while an overly aggressive setting may fail to provide the desired mechanical benefits.
5. What protection functions are available on the ATS48C59Q?
The ATS48C59Q incorporates several protection functions intended to protect both the motor and the soft starter during operation. These include motor thermal protection, starter thermal protection, and line phase-failure detection.
Motor thermal protection helps monitor the thermal condition associated with motor operation, which is particularly important when the motor experiences heavy loading or repeated starting cycles. Starter thermal protection helps prevent excessive thermal stress within the soft starter’s power components.
The device also monitors line phase conditions. A phase failure can cause abnormal motor current and uneven motor operation, so detecting this condition allows the system to respond before prolonged operation causes additional problems.
Protection settings should be configured according to the actual motor nameplate data and application conditions. Incorrect protection settings can either cause nuisance trips or provide insufficient protection, so commissioning should include verification of the relevant motor and starter parameters.
6. How can the ATS48C59Q communicate with a PLC or automation system?
The ATS48C59Q provides Modbus communication through an RS485 multidrop serial interface. The communication connection uses an RJ45 connector, and supported transmission rates include 4800, 9600, and 19200 bps.
Through the communication interface, the soft starter can exchange operating information and control-related data with an automation system such as a PLC or supervisory controller. This can allow centralized monitoring of motor status, starter status, operating parameters, and diagnostic information.
When integrating the ATS48C59Q into a control network, the communication parameters must be configured consistently with the master device. Network addressing, baud rate, wiring, termination, and communication settings should all be checked during commissioning. A communication problem should be distinguished from a power-stage or motor fault because the motor and starter can remain electrically functional even when communication with the PLC is unavailable.
7. What should be checked if the ATS48C59Q trips during motor starting?
If the ATS48C59Q trips during starting, the first step is to identify the specific diagnostic or protection condition rather than immediately changing the starter. The motor nameplate data, starting current, acceleration time, load characteristics, and selected starting parameters should be reviewed.
The motor and mechanical load should also be checked for excessive resistance or mechanical blockage. A pump, conveyor, compressor, or other driven machine with abnormal mechanical loading can require substantially more starting torque than expected, causing the starter to remain in the acceleration phase for too long.
Electrical conditions should also be examined, including supply voltage, phase balance, motor connections, and incoming phase continuity. If the starter detects a phase-related problem, the line supply and motor wiring should be checked before adjusting software parameters.
For repeated-start applications, the number of starts, starting duration, and recovery time between starts should also be considered. Excessive repeated starting can create thermal stress even when individual starts appear normal. Troubleshooting should therefore consider the complete electrical, mechanical, and thermal operating conditions.
8. Can the ATS48C59Q be used for both standard-duty and heavy-duty applications?
Yes. The ATS48C59Q can be configured for different application conditions, but the permissible motor power and operating characteristics depend on the duty level, motor connection, supply voltage, and starting requirements. Schneider’s specifications distinguish between standard and severe applications, particularly when determining the applicable motor power.
For example, at 400 V, the ATS48C59Q can support up to 315 kW for a standard in-line application, while higher motor power ratings are possible under specified inside-delta configurations. Severe-duty applications have different permissible ratings because the thermal and starting requirements are more demanding.
Before selecting the ATS48C59Q, the motor’s rated current, load torque, acceleration time, number of starts per hour, supply voltage, and connection method should be evaluated. Correct application sizing is more important than simply matching the motor’s nominal kW rating. This is especially true for pumps and heavy industrial machinery where starting conditions can vary significantly with the process load.
Schneider ATS48C59Q Soft Starter is in stock. Please contact us for a quick quote and competitive pricing.
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8615305023276 | |||||||
| +8615305023276 | ||||||||
| 13950166376 | ||||||||
| Add to | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Company Introduction
Xiamen Shengruite Trading Co., Ltd. is a company specializing in the supply of industrial PLC spare parts.
We provide high-quality PLC spare parts to customers in the global manufacturing, energy and power, chemical and other fields.
Since its establishment in 2011, after 13 years of rapid development, the cumulative global shipments have reached 223,650 pieces, with an annual output value of US$50 million.
Successfully served more than 500 customers in more than 100 countries and regions including Saudi Arabia, UAE, the United States, Europe, Africa, and Southeast Asia
Our Mission
Provide customers with the best quality PLC spare parts and the fastest delivery service to ensure that their industrial automation systems are always in the best operating condition.
We provide a 1-year warranty service, and we support returns and exchanges for any issues to ensure your rights and interests are fully protected.
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation to ensure you have all the information you need before making a purchase.
Shipping times vary depending on your location. With the support of our 16 global warehouses, we strive to deliver orders as quickly as possible. Contact us to get an estimated delivery time for your specific location.
The minimum order quantity (MOQ) is typically one unit. However, for larger orders, please contact us for potential discounts and pricing details.
Yes, we offer competitive pricing for bulk purchases. Please reach out to our sales team with the specifics of your order to receive a custom quote.
We accept various payment methods for wholesale orders, including bank transfers (T/T), letters of credit, and other options upon agreement. For large transactions, please contact us directly for payment terms.
Yes, we offer flexible ordering options for both small and large quantities. Whether youre looking for a single unit or a large batch, we can accommodate your needs.
We occasionally offer promotional discounts for new wholesale customers. Contact us to learn more about any current offers available for first-time buyers.
If you are unsure of compatibility with your existing setup please provide your system details and our support team can verify compatibility prior to purchase.
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Please note that return shipping and associated costs are the buyer\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\’s responsibility.
Yes, we offer technical support for the installation and integration of our products. Our team can assist with setup, configuration, and troubleshooting to ensure a smooth installation.